Hobart Welding Products XVX manual Variable Shade Control No, 40−80 80−175, 50−100, 60−150, 50−200

Page 7

3-4. Variable Shade Control (No. 9 − 13)

1 Variable Shade Control

(No. 9 − 13)

Use the control to adjust the lens shade in the darkened state. Use the table below to select proper

1shade control setting based on your welding process.

Start at shade 12 and adjust lighter to suit the welding application and your personal preference.

Application Welding

Arc Current in Amperes

Protective Shade No.

 

 

 

Stick Electrodes

Less than 40

9

 

40−80

10

 

80−175

11

 

175−300

12

 

300−500

13

 

 

 

MIG

Less than 100

10

 

100−175

11

 

175−300

12

 

300−500

13

 

 

 

Gas Tungsten Arc Welding

Less than 50

10

(TIG)

50−100

11

 

100−200

12

 

200−400

13

 

 

 

Air Carbon

Less than 500

12

 

500−700

13

 

 

 

Plasma Arc Cutting

60−150

11

 

150−250

12

 

250−400

13

 

 

 

Plasma Arc Welding

Less than 50

9

 

50−200

10

 

200−400

12

 

 

 

OM-240 362 Page 5

Image 7
Contents 2008−11 OM-240 362BTable of Contents Noise can damage hearing − Safety Precautions − Read Before UsingSymbol Usage Hazards ARC Rays can burn eyes and skinStorage Temperature −4F to 158F / −20C to +70C − SpecificationsVariable Shade Control See − Operating InstructionsHelmet Controls See SectionLens Delay Control Reset Button And Low Battery Indicator60−150 Variable Shade Control No −40−80 80−175 50−100Grind Mode Recommended Sensitivity SettingsWeld Mode 130−50% sensitivity setting for most ap Plications− Adjusting Headgear Replacing Outside Lens Cover − Replacing the Lens CoversLens without the inside Replacing Inside Lens Cover Lens Assembly Inside Lens Cover− Replacing the Battery − Maintenance − Installing Optional Magnifying Lens− Troubleshooting Prowler Auto-Darkening Welding Helmet − Parts ListPart Description Quantity Effective January 1 − Limited WarrantyPage Page Hobart Welders