SECTION 5 − INSTALLATION
5-1. Installing Welding Gun
6
Spool Gun
5
MIG Gun
1 | 3 | 4 | 2 |
|
|
.Be sure that gun end is tight against drive assembly.
3 | 3 |
1Drive Assembly
2MIG Gun
3Gun Securing Thumbscrew
4Gun End
Loosen thumbscrew. Insert end through opening until it bottoms against drive assembly. Tighten thumbscrew.
Welding gun must be inserted completely to prevent leakage of shielding gas.
5 Gun Trigger Plug
Insert plug into receptacle, and tighten threaded collar.
6Spool Gun/MIG Gun Switch Place switch in MIG Gun position. Close door.
| Exposed |
|
Incorrect | will cause shielding | Correct |
gas leakage. | ||
Gun Not Seated |
| Gun Fully Seated |
804
5-2. Installing Work Clamp
.Connection hardware must be tightened with proper tools. Do not just hand tighten hardware. A loose electrical connection will cause poor weld performance and excessive heating of the work clamp.
3
1
6
2
Tools Needed: | 5 | 4 |
| 7/16 in |
|
1Nut
2Work Cable From Unit
3Work Clamp
4Screw
5Work Clamp Tabs
Bend tabs around work cable.
6 Insulating Sleeves
Slide one insulating sleeve over work cable before connecting to clamp.
Slide insulating sleeves over handles.
7/16 in
802