Hobart Welding Products 2250 specifications Changing Input Voltage From 230 Volts To 200 Volts

Page 17

2-9. Changing Input Voltage From 230 Volts To 200 Volts

 

 

Cut cable ties as necessary.

 

 

1

230 Volt Transformer

 

 

 

Lead/Fan Lead

 

2

2

Black Switch Lead

 

3

Tubing

 

 

 

 

Locate lead marked 230 VAC.

 

 

Slide tubing down and disconnect

 

 

black switch lead from splice. Be

 

 

sure 230 volt transformer lead and

 

3

white fan lead remain spliced.

 

 

Fold tubing over 230 volt transform-

 

 

er/fan lead splice and secure.

4

 

4

200 Volt Lead

200 VAC

1

Locate lead marked 200 VAC.

 

 

Slide tubing down, and connect 200

230 VAC

volt lead stub to black switch lead

 

that was just disconnected from the

 

230 volt lead, and secure with exist-

 

ing hardware.

 

Slide tubing over connection and

 

secure.

Tools Needed:

5/16, 3/8 in

Ref. ST-802 287

2-10. Electrical Service Guide

Input Voltage

200

230

 

 

 

Input Amperes At Rated Output

40

35

 

 

 

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

60

50

 

 

 

Min Input Conductor Size In AWG/Kcmil

8

10

 

 

 

Max Recommended Input Conductor Length In Feet (Meters)

108 (33)

94 (29)

 

 

 

Min Grounding Conductor Size In AWG/Kcmil

10

10

 

 

 

Reference: 1996 National Electrical Code (NEC)

 

S-0092J

 

 

 

OM-192 440 Page 13

Image 17
Contents Description ProcessesFrom Hobart to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards About Pacemakers EMF InformationConsignes DE Securite Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un incendie ou une explosionDES Pièces Chaudes peuvent pro- voquer des brûlures graves LE Bruit peut affecter l’ouïeLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sécuritéInformation sur les champs électromagnétiques Exceeding duty cycle can damage unit and void warranty SpecificationsIntroduction Duty Cycle And OverheatingVolt-Ampere Curves Installing Welding GunSetting Gun Polarity For Wire Type Installing Work ClampInstalling Wire Spool And Adjusting Hub Tension Installing Gas SupplyChanging Input Voltage From 230 Volts To 200 Volts Electrical Service GuideInput Voltage Min Grounding Conductor Size In AWG/KcmilSelecting a Location And Connecting Input Power Hold wire tightly to keep it from unraveling Threading Welding WireControls OperationWeld Parameters Routine Maintenance Maintenance and TroubleshootingCircuit Breakers MonthsReplacing Gun Contact Tip Replacing Drive Roll And Wire Inlet GuideTurn Off power before replacing contact tip To Reassemble Gun Cleaning Or Replacing Piecemaker 20-A Gun LinerDisconnect gun from unit Wire Drive/Gun Troubleshooting Table Welding Troubleshooting TableWire Drive/Gun Trouble Remedy Welding Trouble RemedyCircuit Diagram For Welding Power Source Electrical DiagramOM-192 440 Main Assembly Parts ListItem Dia Part Mkgs Description Quantity Center Baffle w/Components Center Baffle w/Components -1 Item Rear Panel w/Components Front Panel w/Components Gun And Cable Assembly, Piecemaker 20-A Part Description Quantity Page Page Page Call Effective January 1Hobart Welding Products Contact your Distributor for