3.2
English
3.2Switch Box
The switch box is located in the heat pump. All electrical compo- nents are accessible after the front cover and the switch box cover have been removed.
The switch box contains the supply connection terminals, the plug connector for the control line, as well as the power contac- tors and the soft starter unit.
3.3Heat Pump Controller
Use the heat pump controller included in the scope of supply to operate the
The heat pump controller is a convenient electronic regulation and control device. It controls and monitors the entire heating system on the basis of the external temperature, including do- mestic hot water preparation and safety systems.
The customer must install the return temperature sensor and the external temperature sensor, which are supplied with the heat pump controller / with these instructions together with the neces- sary fixing accessories.
The enclosed operating instructions describe the function and use of the heat pump controller.
4 Transport
ATTENTION!
Never install the device in rooms in which there are any permanent ignition sources.
ATTENTION!
When transporting the heat pump, ensure that it is not tilted more than 45° (in any direction).
Use a wooden pallet for transporting the heat pump to the final in- stallation location. The basic device can be transported with a lift truck, hand truck or by means of 3/4" pipes fed through the holes in the base plate or frame.
ATTENTION!
The heat pump and transport pallet are only joined by the packing film.
Before using the transport holes in the frame, it is necessary to remove the lower side panel assemblies. This is done by loosen- ing each of the two screws at the base and then withdrawing the panels by unhooking them from above. Rehang the panels by gently pushing them in an upwards direction.
Be careful not to damage any components when inserting the pipes through the frame.
Opening the cover
Closing the cover