230 Volt Operation

If 230V, single phase operation is desired, the following instructions must be followed:

1.Disconnect the machine from the power source.

2.This JET drill press is supplied with four motor leads that are connected for 115V operation, as shown in Figure A. Reconnect these four motor leads for 230V operation, as shown in Figure B.

3.The 115V attachment plug (A), supplied with the drill press, must be replaced with a UL/CSA listed plug suitable for 230V operation (D). Contact your local Authorized JET Service Center or qualified electrician for proper procedures to install the plug. The drill press must comply with all local and national codes after the 230 volt plug is installed.

4.The drill press with a 230 volt plug should only be connected to an outlet having the same configuration (D). No adapter is available or should be used with the 230 volt plug.

Important: In all cases (115 or 230 volts), make certain the receptacle in question is properly grounded. If you are not sure, have a registered electrician check the receptacle.

6

Image 6
Contents JDP-17FSE JET Drill Press Warranty & Service Total Length of Cord in Feet AWGPage Grounding Instructions Volt OperationDisconnect the machine from the power source On-Off Switch Padlock Model No. BP-1, Stock NoSpecifications Table of ContentsContents of the Shipping Container Tools Supplied for AssemblyTools Required for Assembly Assembly Unplug machine from the power source Removing the Chuck and ArborAdjusting the Depth Stop Unplug the machine from the power sourceChanging Spindle Speeds Speed & Pulley Chart Return Spring Adjustment Table Tilt AdjustmentBasic Operation LubricationTroubleshooting Parts Breakdown for JDP-17FSE Parts List for JET JDP-17FSE Drill Press Index Part Description Size Qty10705703