Grounding Instructions
3 HP Single Phase Motor
Electrical connections must be made by a qualified electrician in compliance with all relevant codes. This machine must be properly grounded to help prevent electrical shock and possible fatal injury.
This machine must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
Improper connection of the equipment- grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes, is the equipment- grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the
Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the tool is properly grounded.
Repair or replace a damaged or worn cord immediately.
Make sure the voltage of your power supply matches the specifications on the motor plate of the band saw. The machine should be connected to a dedicated circuit.
230 Volt Operation
If your band saw's Stock No. is 710751, it is wired from the factory for 230 volt operation You may either install a plug or
If connecting a plug, use a proper UL/CSA listed
If the band saw is to be
operator. During
Extension cords
The use of an extension cord is not recommended for this band saw. But if one is necessary, make sure the cord rating is suitable for the amperage listed on the machine’s motor plate. An undersize cord will cause a drop in line voltage resulting in loss of power and overheating.
Use the chart in Table 1 as a general guide in choosing the correct size cord. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
Recommended Gauges (AWG) of Extension Cords
|
| Extension Cord Length * |
| |||
|
|
|
|
|
|
|
Amps | 25 | 50 | 75 | 100 | 150 | 200 |
feet | feet | feet | feet | feet | feet | |
|
|
|
|
|
|
|
< 5 | 16 | 16 | 16 | 14 | 12 | 12 |
|
|
|
|
|
|
|
5 to 8 | 16 | 16 | 14 | 12 | 10 | NR |
|
|
|
|
|
|
|
8 to 12 | 14 | 14 | 12 | 10 | NR | NR |
|
|
|
|
|
|
|
12 to 15 | 12 | 12 | 10 | 10 | NR | NR |
|
|
|
|
|
|
|
15 to 20 | 10 | 10 | 10 | NR | NR | NR |
|
|
|
|
|
|
|
21 to 30 | 10 | NR | NR | NR | NR | NR |
|
|
|
|
|
|
|
*based on limiting the line voltage drop to 5V at 150% of the rated amperes.
NR: Not Recommended.