Trouble | Probable Cause | Remedy | |
|
|
| |
|
| If electric motor is suspect, you have | |
|
| two options: Have a qualified | |
| Motor failure. | electrician test the motor for function | |
| or remove the motor and take it to a | ||
|
| ||
|
| qualified electric motor repair shop | |
|
| and have it tested. | |
|
|
| |
Machine will not |
| Double check to confirm all electrical | |
| connections are correct. Refer to | ||
start/restart or |
| ||
Miswiring of the unit. | appropriate wiring diagrams on pages | ||
repeatedly trips | |||
| 40 and 41 to make any needed | ||
circuit breaker or |
| ||
| corrections. | ||
blows fuses. |
| ||
|
| ||
|
| If the start/stop switch is suspect, you | |
|
| have two options: Have a qualified | |
| Switch failure. | electrician test the switch for function, | |
| or purchase a new start/stop switch | ||
|
| ||
|
| and establish if that was the problem | |
|
| on changeout. | |
|
|
| |
Band Saw does not | Extension cord too light or too long. | Replace with adequate size and | |
come up to speed. | length cord. | ||
| |||
|
|
| |
| Low current. | Contact a qualified electrician. | |
|
|
|
27