Adjusting 90° Table Stop
1.Disconnect machine from the power source.
2.Loosen lock knobs (Fig. 14) and tilt table left until it rests against table stop.
3.Use a square placed on the table and against the blade (Fig. 15) to see if the table is 90 degrees to the blade.
4.If an adjustment is necessary, loosen lock knobs, tilt table to the right, and lock in place.
5.Loosen jam nut and turn table stop (Fig. 14) left or right to raise or lower the stop. Tighten jam nut to hold table stop in place.
6.Unlock table, tilt back onto table rest and confirm table is 90 degrees with the blade.
7.If necessary, adjust scale pointer to zero.
Changing Blades
WARNING
Blade teeth are sharp! Use care when
handling the saw blade.
Failure to comply may cause serious injury!
1. Disconnect machine from power source.
2. Loosen blade tension by pushing up on the release lever (Fig. 16).
3. Remove the table insert and the table pin.
4. Open both wheel covers.
5. Remove the blade from between upper and lower blade guides. Remove blade from upper and lower wheels. Turn blade to direct through slot in table.
6. Guide new blade through table slot. Place blade in upper and lower blade guides. Note: Make sure blade teeth point down toward table.
7. Place blade in the middle of the upper and lower wheel.
8. Replace table insert and table pin.
15