MAINTENANCE
LUBRICATION
Perform maintenance below after each 20 hours of use.
1.DISCONNECT MACHINE FROM POWER SOURCE.
2.Remove the four screws (A) Fig. 26, and side panel
(B).
3.Release blade tension by moving blade tension lever to the vertical position.
4.Remove the two pivot bolts and wave washers (C) Fig. 27.
5.Fig. 28 illustrates one of the pivot bolts and wave washers (C) removed. Thoroughly clean grease from shafts of both pivot bolts and lubricate shafts with a few drops of light machine oil.
6.Re-assemble the two pivot bolts and replace side panel. Re-apply tension to the blade.
A BA
Fig. 26
C
Fig. 27
C
Fig. 28
12