Allied Air Enterprises 4AC18LT manual Torque Table, Installation Clearances, General

Page 2

INSTALLATION

General

Read this entire instruction manual, as well as the instructions supplied in separate equipment, before starting the installation. Observe and follow all warnings, cautions, instructional labels, and tags. Failure to comply with these instructions could result in an unsafe condition and/or premature component failure.

These instructions are intended as a general guide only for use by qualified personnel and do not supersede any national or local codes in any way. The installation must comply with all provincial, state, and local codes as well as the National Electrical Code (U.S.) or Canadian Electrical Code (Canada). Compliance should be determined prior to installation.

4AC18LT condensing units use R410A which is an ozone- friendly HFC refrigerant. The unit must be installed with a matching indoor coil and line set. 4AC18LT units are designed for use in expansion valve (TXV) systems only. A filter drier approved for use with R410A is installed in the unit.

IMPORTANT: This product has been designed and manufactured to meet ENERGY STAR criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow the manufacturer’s refrigerant charging and air flow instructions. Failure to confirm proper charge and airflow may reduce energy efficiency and shorten equipment life.

Torque Table

Fastener

Torque

 

 

Stem Caps

8 ft. lbs.

 

 

Service Port Caps

8 ft. lbs.

 

 

Sheet Metal Screws

16 in. lbs.

 

 

#8 Machine Screws

16 in. lbs.

 

 

#10 Machine Screws

28 in. lbs.

 

 

Compressor Bolts

90 in. lbs.

 

 

Table 1

When servicing or repairing HVAC components, ensure the fasteners are appropriately tightened. Table 1 shows torque values for fasteners.

Inspection of Shipment

Upon receipt of equipment, carefully inspect it for possible shipping damage. If damage is found, it should be noted on the carrier’s freight bill. Take special care to examine the unit inside the carton if the carton is damaged. Any concealed damage discovered should be reported to the last carrier immediately, preferably in writing, and should include a request for inspection by the carrier’s agent.

If any damages are discovered and reported to the carrier DO NOT INSTALL THE UNIT, as claim may be denied.

Check the unit rating plate to confirm specifications are as ordered.

Location of Unit

Outdoor units operate under a wide range of weather conditions; therefore, multiple factors must be considered when positioning the unit. The unit must be positioned to give adequate clearances for sufficient airflow and servicing. Refer to Figure 1 for installation clearances.

Installation Clearances

36”

36” *

36”

36” *

*A service clearance of 30" must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36". Clearance to one of the remaining two sides may be 12" and the final side may be 6".

A clearance of 24" must be maintained between units.

48" clearance required on top of unit. Maximum soffit overhang is 36".

Figure 1

506469-01

Issue 1008

Page 2 of 24

Image 2
Contents 4AC18LT Series Lennox International Inc. CompanyTorque Table InstallationInstallation Clearances GeneralSlab Mounting Electrical WiringSlab Mounting Roof MountingLine Set Isolation PlacementOutside Unit Placement & Installation Refrigerant Line Set DiametersRefrigerant Piping Installing Refrigerant LineThermostat Designations Refrigerant Line Sets Installing Horizontal Runs Refrigerant Line Sets Transition from Vertical to Horizontal Flushing Procedure Required EuipmentTXV Data Refrigerant Metering DeviceExpansion Valve Systems To Access the Schrader Port To Close Liquid or Suction Line Service ValveUsing an Electronic Leak Detector EvacuationIssue Refrigerant Charging Refrigerant Charge AdjustmentSTART-UP Blocking Outdoor Coil Subcooling Values R410A Temperature/Pressure ChartCheck Charge Using Normal Operating Pressures Approach Values for TXV SystemsIssue Operation Flash Codes Flash Codes Miswired Module Troubleshooting Indoor Unit MaintenanceIndoor Coil Start-Up and Performance Checklist Wire Diagram Issue

4AC18LT specifications

Allied Air Enterprises has made significant strides in the HVAC industry with the introduction of its 4AC18LT air conditioner. This model is part of a premium line of products that emphasizes efficiency, reliability, and advanced cooling technology. The 4AC18LT is specifically designed to meet the diverse needs of both residential and light commercial applications, making it a versatile choice for many consumers.

One of the standout features of the 4AC18LT is its impressive Seasonal Energy Efficiency Ratio (SEER) rating. With a SEER rating of up to 18, this unit is engineered to provide excellent energy efficiency, significantly reducing electricity consumption while delivering consistent cooling performance. As energy costs continue to rise, homeowners and businesses can benefit greatly from this efficiency, leading to lower monthly utility bills and a reduced carbon footprint.

The 4AC18LT employs advanced R-410A refrigerant, which is known for its environmentally friendly properties. Unlike older refrigerants that contribute to ozone depletion, R-410A is more stable and offers better heat transfer capabilities, which enhances the overall performance of the unit. This focus on eco-friendliness aligns with contemporary environmental standards and regulations, ensuring that users are making a responsible choice for their cooling needs.

In terms of design, the 4AC18LT features a robust and compact frame that is built to withstand the rigors of outdoor installation. The unit's durability is further enhanced by its corrosion-resistant finish, which protects the coil and cabinet from harsh weather conditions, extending the life span of the system.

Noise reduction technology is another highlight of the 4AC18LT. This model is designed with a quieter operation in mind, utilizing a sound blanket and insulated compressor compartment. These features work together to minimize noise levels, allowing users to enjoy a comfortable indoor environment without disruptive sound.

The 4AC18LT also supports advanced controls and compatibility with smart thermostats, providing users with greater flexibility and convenience. Homeowners can take advantage of programmable features, enabling them to optimize cooling schedules for energy savings and increased comfort.

Overall, Allied Air Enterprises’ 4AC18LT air conditioner combines efficiency, environmental responsibility, durability, and user-friendly features, making it an excellent choice for those in need of reliable cooling solutions. Whether installed in a residential or light commercial setting, the 4AC18LT promises to deliver exceptional performance and peace of mind.