Carrier ASPAS1CCA015, ASPAS1CCA012 manual SP1 IM1 SP2 IM2

Page 18

Section 4 - Electrical Data

Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators

Wiring Diagram — V-Twin — Drawing No. 0E9016

ENGINE WIRING

 

 

 

3

 

 

DIAGRAM KEY

 

2

 

 

 

1 BATTERY

 

 

 

 

 

BA

- BRUSH ASSEMBLY

 

CHARGER

 

 

 

 

BCR - BATTERY CHARGE RELAY

 

 

2

CB1 - MAIN OUTPUT BREAKER

 

 

14

0 13

1

CB2 - CIRCUIT BREAKER, ALTERNATOR EXCITATION

CB3 - CIRCUIT BREAKER, EXTERNAL OUTLET, PUSH/PULL

 

 

225B

D

- DIODE

 

 

 

DSW - PCB MOUNTED DIP SWITCH

 

 

224B

FS

- FUEL SOLENOID

FS

13

13

F1

- FUSE 15 AMP

F2

- FUSE 7.5 AMP

 

0

0

GRD - CONTROL PANEL GROUND

 

14

 

224B

HTO - HIGH OIL TEMPERATURE SWITCH

 

 

 

IC - INLINE CONNECTOR

 

 

225B

ICT - INTERCONNECTION TERMINALS

0

 

 

 

IM1 - IGNITION MODULE, CYLINDER #1

 

 

 

 

 

IM2 - IGNITION MODULE, CYLINDER #2

 

 

 

LOP - LOW OIL PRESSURE SWITCH

 

 

14

SC - STARTER CONTACTOR

 

 

SCR - STARTER CONTACTOR RELAY

 

0

0

SP1, SP2 - SPARK PLUGS

 

 

 

 

SW1 - AUTO / OFF / MANUAL SWITCH

14

 

 

SW2 - SET EXERCISE SWITCH

 

14

 

SM

- STARTER MOTOR

 

 

 

14

 

TB

- INSULATED TERMINAL BLOCK

 

 

 

 

 

TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.)

IC

 

 

D

 

 

 

 

 

 

TB

 

 

SP1

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

6

0

 

 

 

 

 

 

IM1

 

 

18

5

18

 

 

 

 

 

 

 

 

 

85

4

 

 

 

 

 

 

 

 

 

 

86

3

 

 

 

 

 

 

SP2

 

D

 

13

2

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IC

 

1

16

 

 

 

 

 

 

 

 

 

C1

85

 

 

 

 

 

 

IM2

 

 

 

 

 

 

 

 

 

 

IC

 

 

86

 

 

 

 

 

 

 

 

85

 

 

16

 

 

 

 

 

 

 

16

 

SCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

85

 

 

 

 

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HTO

 

 

86

 

 

 

 

 

351

 

 

 

 

 

 

 

 

56

0

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

86

 

 

 

 

 

1

2

3

4

5

 

 

 

 

 

 

 

 

 

J2

 

 

LOP

 

 

 

 

 

 

 

 

 

 

J1

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

 

 

PRINTED CIRCUIT BOARD

BLACK

 

 

RED

 

 

 

DSW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

1 2 3 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

ON - INDICATES

 

 

 

-

+

 

SM

16

 

1 - 20 Vac Sense Transformer

 

 

 

2 - Remote Not Auto

 

 

 

 

 

 

 

 

 

12V

 

 

 

 

3 - 50 Hz Operation

 

 

BATTERY

 

 

 

 

4 - SPARE

 

 

 

 

CUSTOMER SUPPLIED

 

 

SC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L.E.D - ALARM INDICATORS

14

18

56

86

17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

0

13

15

351

18

56 14

4

86

23

194

56

18

14

66A

239

15A

17

15

0

225

224

16 Carrier

Image 18
Contents Parts, Adjustment and Maintenance Manual Introduction ‹ Read this Manual ThoroughlyImportant Safety Instructions General Hazards Electrical Hazards Check Transfer Switch Operation Before Initial START-UPElectrical Checks Adjusting the Regulator Natural GAS only Generator Tests Under LoadChecking Automatic Operation Reconfiguring the Fuel System Unit VoltsEngine Governor Adjustment 2 12KW and 15KW, V-TWIN EnginesVoltage Regulator Adjustment Valve ClearanceValve Clearance Adjustment Troubleshooting Guide Problem Cause CorrectionService Schedule Be performed by the nearest Carrier DealerElectrical Data Customer Battery Utility SP1 IM1 SP2 IM2 Customer Connection Battery Charge 1VA Electrical Data Electrical Data Electrical Data Electrical Data ATS N2A N1A 51 9 3651 9115 QTY Description Carrier SOCKET, 12VDC Accessory ASSEMBLY, Home StandbyWire CONTROL, Panel Bottom Pull Main ResetCarrier BOX GTS Load Center Transfer Switch Home Standby 100A 2PLimit Switch Operation not Shown COVER, 8 Position GTS Load CenterCarrier COVER, 10 Position GTS Load Center Wire HARNESS,GTS Load Center not Shown for ClarityCOVER, 12 Position GTS Load Center Washer Flat 1/4-M6 ZincCarrier CRANKCASE, Subassembly with Plugs GH410 ASSEMBLY, Connecting RODASSEMBLY, Crankshaft GH410 Small Taper ASSEMBLY, Governor GearCarrier SWITCH, OIL 8.0 PSI HOUSING, BlowerASSEMBLY, Plastic Carb ASSEMBLY,GOVERNOR Lever 12 HP1310 ASSEMBLY, OIL Fill CAP ASSEMBLY, BreatherASSEMBLY, Head #1 G&S ASSEMBLY,GOVERNOR Gear122 138 ELEMENT, AIR Cleaner Chrome KNOB, AIR CleanerPRE-CLEANER ASSEMBLY, MIXER/AIRBOXCarrier BASE, AIR Cleaner CABLE, #6 40 Black BatteryAssembly Brush Holder ELEMENT, AIR CleanerCarrier Stator 13KW / 15KW CABLE, #6 48 Black BatteryStator 12KW Rotor 12KWAdjuster SCREW, Twin HousingAssembly PIN, Limited AdjustmentCarrier Air-cooled Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators Catalog no AS-PA0 Form ASPAS07-1PD

ASPAS1CCA012, ASPAS1CCA015 specifications

The Carrier ASPAS1CCA015 and ASPAS1CCA012 are advanced air conditioning units designed to offer superior climate control in residential and light commercial settings. Both models reflect Carrier's commitment to innovation, energy efficiency, and user comfort.

One of the primary features of these units is their inverter technology. This smart technology adjusts the compressor speed in real-time, allowing the system to operate efficiently and maintain a consistent temperature. This results in reduced energy consumption and lower utility bills while providing a more comfortable indoor environment.

The ASPAS1CCA015 and ASPAS1CCA012 also include a state-of-the-art air filtration system. These units are equipped with a high-efficiency particulate air (HEPA) filter that effectively captures dust, allergens, and pollutants. This feature contributes to improved indoor air quality, making them ideal for allergy sufferers and those concerned about indoor air pollution.

In terms of performance, both models deliver impressive cooling and heating capacities. The ASPAS1CCA015 has a cooling capacity of 15,000 BTUs, while the ASPAS1CCA012 offers a cooling capacity of 12,000 BTUs. This range makes them suitable for various room sizes, ensuring effective temperature management whether during scorching summers or chilly winters.

A user-friendly digital thermostat and Wi-Fi connectivity are additional features that enhance the usability of these models. Homeowners can control their air conditioning systems remotely via smartphones or tablets, enabling them to adjust settings for optimum comfort and efficiency even when they are not at home.

The units are designed with quiet operation in mind. They utilize advanced silencing technologies, ensuring that noise levels remain low, allowing for peaceful environments during night-time or in quiet settings. This is particularly beneficial for bedrooms, nurseries, or offices where distraction-free air conditioning is essential.

Moreover, both models are compliant with the latest standards for energy efficiency, earning high SEER (Seasonal Energy Efficiency Ratio) ratings. This not only promotes environmental sustainability but also aligns with governmental incentives aimed at reducing energy consumption.

In summary, the Carrier ASPAS1CCA015 and ASPAS1CCA012 are equipped with cutting-edge technologies and features that make them reliable and efficient air conditioning solutions. With their inverter technology, advanced filtration systems, remote connectivity, and quiet operation, these units represent a combination of comfort, convenience, and environmental responsibility that meets the needs of modern users.