Carrier ASPAS1CCA012 NUT HEX Lock M5-0.8 Nylon, Insert, Transformer, Fuse 7.55A X AGC5, Engine

Page 31

Section 5 - Exploded Views and Parts

Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators

Control Panel — Drawing No. 0E9162-H

ITEM

PART NO.

QTY.

DESCRIPTION

 

ITEM

PART NO.

QTY.

DESCRIPTION

1

0E7886A

1

CIRCUIT BREAKER 30A X 2P 240V

27

074908

4

SCREW TAPTITE, M5-0.8 x 10 BP

 

 

 

(7KW)

29

082025

6

NUT HEX LOCK M5-0.8 NYLON

 

0E7886E

1

CIRCUIT BREAKER 50A X 2P 240V

 

 

 

 

INSERT

 

 

 

(12KW)

30

0C3910

1

TRANSFORMER

 

0E7886F

1

CIRCUIT BREAKER 60A X 2P 240V

31

022507

2

SCREW HHC 1/4"-20 x 1/2"

 

 

 

(13KW)

32

0A9611

1

FUSE 7.55A X AGC5

 

0E7886G

1

CIRCUIT BREAKER 70A X 2P 240V

33

046689

1

BLOCK TERMINAL STRIP 20A 4 X 6

 

 

 

(15KW LP)

 

 

 

 

X 1100V

2

0A1801

1

ASSEMBLY, BATTERY CHARGER

34

063617

1

RELAY PANEL 12VDC DPDT 10A

 

 

 

ENGINE

 

 

 

 

240VAC

3

083049

1

ASSEMBLY, POTTED REGULATOR

35

075475

4

SCREW PPHM M4-0.7 x 10mm

4

0C2174

1

RELAY, 12V 25A SPST

36

043180

2

WASHER FLAT M4

5

075210A

1

BLOCK 1 POSITION

37

0E8812

1

COVER, CONTROL PANEL

6

0D3062

4

HEX STAND-OFF #6-32 x 3/8"

 

 

 

 

COMPONENT

7

0D8615

1

ASSEMBLY, HOME STANDBY

 

 

0E8895

1

COVER, CONTROL PANEL

 

 

 

CONTROLLER

 

 

 

 

COMPONENT (7KW)

 

0D8615A

1

ASSEMBLY, HOME STANDBY

38

092036

8

SCREW PPHMS/LW #6-32 x 1/4"

 

 

 

CONTROLLER (7KW)

39

045770

2

SCREW HHC M5-0.8 x10mm

8

032300

2

HOLDER, FUSE

40

0E7866

1

COVER, CONTROL PANEL

9

022676

1

FUSE, 15AMP X AGC15

 

 

0E7867

1

COVER, CONTROL PANEL (7KW)

10

0E4494

1

SWITCH, ROCKER DPDT ON-OFF-

41

0D3700

8

NUT FLANGE M6-1.0 NYLOK

 

 

 

ON

42

0912970069

1

ASSEMBLY, ROOF/DOOR GROUND

11

0E7890

1

CIRCUIT BREAKER MOUNTING

 

 

 

 

WIRE

 

 

 

BRACKET

43

0E2874

1

SCREW HHTR 1/4"-20 X 3/4"

12

023484E

1

SNAP BUSHING

44

0A1658

2

WASHER LOCK SPECIAL 1/4"

13

075476

4

SCREW PPHM M4-0.7 x 16mm

45

022473

3

WASHER FLAT 1/4"-M6

15

0E6480

6

NUT HEX LOCK M4-0.7 NYLON

46

038750

1

SCREW HHC M6-1.0 x 30mm

 

 

 

INSERT

47

022097

3

WASHER LOCK M6-1/4"

17

0C1085

6

SCREW PPHM M3-0.5 x 8mm

48

049813

1

NUT HEX M6-1.0

 

0C1085

4

SCREW PPHM M3-0.5 x 8mm (7KW)

49

031879

6

WASHER FLAT #4

19

054502

1

CIRCUIT BREAKER 3 X 1 ETA 46-

 

 

031879

4

WASHER FLAT #4 (7KW)

 

 

 

500-P

50

023897

2

WASHER FLAT #10

 

053623

1

CIRCUIT BREAKER 2.5 X 1 ETA 46-

51

0E9056

1

SOCKET, 12VDC ACCESSORY

 

 

 

500-P (7KW)

52

0E5840

1

CIRCUIT BREAKER 15A PUSH /

20

0E7870

1

CONTROL, PANEL BOTTOM

 

 

 

 

PULL MAIN RESET

 

0E7871

1

CONTROL, PANEL BOTTOM (7KW)

53

036903

6

SCREW PPHM #6-32 X 5/8"

21

075235

4

SCREW HHC M5-0.8 x 30mm

54

0E7833

1

PLATE, WEATHERPROOF GFCI

22

0D5240

1

SWITCH, SPST (ON)-ON N/O

55

0E4261

1

OUTLET, 15A GFCI DUPLEX

23

0D9784

6

NUT HEX LOCK M3-0.5 NYLON

56

022985

4

WASHER FLAT #6

 

 

 

INSERT

57

082625

4

NUT LOCK HEX #6-32 NYL INSERT

 

0D9784

4

NUT HEX LOCK M3-0.5 NYLON

58

0E9171

1

GASKET, WEATHERPROOF GFCI

 

 

 

INSERT (7KW)

59

04793

2

SCREW PPHM, M3-0.5 X 10MM

24

0D8502

1

NEUTRAL CONNECTOR

 

 

 

 

 

26

0E8956

1

HARNESS, CONTROL PANEL (NOT

 

 

 

 

 

 

 

 

SHOWN)

 

 

 

 

 

 

0E8957

1

HARNESS, CONTROL PANEL WIRE

 

 

 

 

 

 

 

 

(NOT SHOWN) (7KW)

 

 

 

 

 

Carrier 29

Image 31
Contents Parts, Adjustment and Maintenance Manual ‹ Read this Manual Thoroughly IntroductionImportant Safety Instructions General Hazards Electrical Hazards Before Initial START-UP Check Transfer Switch OperationElectrical Checks Generator Tests Under Load Adjusting the Regulator Natural GAS onlyChecking Automatic Operation Unit Volts Reconfiguring the Fuel System2 12KW and 15KW, V-TWIN Engines Engine Governor AdjustmentValve Clearance Voltage Regulator AdjustmentValve Clearance Adjustment Problem Cause Correction Troubleshooting GuideBe performed by the nearest Carrier Dealer Service ScheduleElectrical Data Customer Battery Utility SP1 IM1 SP2 IM2 Customer Connection Battery Charge 1VA Electrical Data Electrical Data Electrical Data Electrical Data ATS N2A N1A 51 9 3651 9115 QTY Description Carrier CONTROL, Panel Bottom Pull Main Reset ASSEMBLY, Home StandbyWire SOCKET, 12VDC AccessoryCarrier COVER, 8 Position GTS Load Center Transfer Switch Home Standby 100A 2PLimit Switch Operation not Shown BOX GTS Load CenterCarrier Washer Flat 1/4-M6 Zinc Wire HARNESS,GTS Load Center not Shown for ClarityCOVER, 12 Position GTS Load Center COVER, 10 Position GTS Load CenterCarrier ASSEMBLY, Governor Gear ASSEMBLY, Connecting RODASSEMBLY, Crankshaft GH410 Small Taper CRANKCASE, Subassembly with Plugs GH410Carrier ASSEMBLY,GOVERNOR Lever 12 HP HOUSING, BlowerASSEMBLY, Plastic Carb SWITCH, OIL 8.0 PSI1310 ASSEMBLY,GOVERNOR Gear ASSEMBLY, BreatherASSEMBLY, Head #1 G&S ASSEMBLY, OIL Fill CAP122 138 ASSEMBLY, MIXER/AIRBOX KNOB, AIR CleanerPRE-CLEANER ELEMENT, AIR Cleaner ChromeCarrier ELEMENT, AIR Cleaner CABLE, #6 40 Black BatteryAssembly Brush Holder BASE, AIR CleanerCarrier Rotor 12KW CABLE, #6 48 Black BatteryStator 12KW Stator 13KW / 15KWPIN, Limited Adjustment HousingAssembly Adjuster SCREW, TwinCarrier Air-cooled Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators Catalog no AS-PA0 Form ASPAS07-1PD

ASPAS1CCA012, ASPAS1CCA015 specifications

The Carrier ASPAS1CCA015 and ASPAS1CCA012 are advanced air conditioning units designed to offer superior climate control in residential and light commercial settings. Both models reflect Carrier's commitment to innovation, energy efficiency, and user comfort.

One of the primary features of these units is their inverter technology. This smart technology adjusts the compressor speed in real-time, allowing the system to operate efficiently and maintain a consistent temperature. This results in reduced energy consumption and lower utility bills while providing a more comfortable indoor environment.

The ASPAS1CCA015 and ASPAS1CCA012 also include a state-of-the-art air filtration system. These units are equipped with a high-efficiency particulate air (HEPA) filter that effectively captures dust, allergens, and pollutants. This feature contributes to improved indoor air quality, making them ideal for allergy sufferers and those concerned about indoor air pollution.

In terms of performance, both models deliver impressive cooling and heating capacities. The ASPAS1CCA015 has a cooling capacity of 15,000 BTUs, while the ASPAS1CCA012 offers a cooling capacity of 12,000 BTUs. This range makes them suitable for various room sizes, ensuring effective temperature management whether during scorching summers or chilly winters.

A user-friendly digital thermostat and Wi-Fi connectivity are additional features that enhance the usability of these models. Homeowners can control their air conditioning systems remotely via smartphones or tablets, enabling them to adjust settings for optimum comfort and efficiency even when they are not at home.

The units are designed with quiet operation in mind. They utilize advanced silencing technologies, ensuring that noise levels remain low, allowing for peaceful environments during night-time or in quiet settings. This is particularly beneficial for bedrooms, nurseries, or offices where distraction-free air conditioning is essential.

Moreover, both models are compliant with the latest standards for energy efficiency, earning high SEER (Seasonal Energy Efficiency Ratio) ratings. This not only promotes environmental sustainability but also aligns with governmental incentives aimed at reducing energy consumption.

In summary, the Carrier ASPAS1CCA015 and ASPAS1CCA012 are equipped with cutting-edge technologies and features that make them reliable and efficient air conditioning solutions. With their inverter technology, advanced filtration systems, remote connectivity, and quiet operation, these units represent a combination of comfort, convenience, and environmental responsibility that meets the needs of modern users.