Carrier ASPAS1CCA012, ASPAS1CCA015 manual Electrical Hazards

Page 5

ELECTRICAL HAZARDS

All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as well as the standby generator. Avoid contact with bare wires, terminals, connections, etc., on the generator as well as the transfer switch, if applicable. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If work must be done around an operating unit, stand on an insulated, dry surface to reduce shock hazard.

Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet.

DANGEROUS ELECTRICAL SHOCK MAY RESULT.

If people must stand on metal or concrete while installing, operating, servicing, adjusting or repairing this equipment, place insulative mats over a dry wooden platform. Work on the equipment only while standing on such insulative mats.

The National Electrical Code (NEC) requires the frame and external electrically conductive parts of the generator to be connected to an approved earth ground. This grounding will help prevent dangerous electrical shock that might be caused by a ground fault condition in the generator set or by static electricity. Never disconnect the ground wire. Local electrical codes also may require proper grounding of the generator electrical system.

After installing this home standby electrical system, the generator may crank and start at any time without warning. When this occurs, load circuits are transferred to the STANDBY (generator) power source. To prevent possible injury if such a start and transfer occur, always set the generator's Auto/Off/Manual switch to its OFF position before working on equipment and remove the 7.5A and 15A fuses from the generator control panel.

In case of accident caused by electric shock,immediately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting implement, such as a dry rope or board, to free the victim from the live conductor. If the victim is unconscious, apply first aid and get immediate medical help.

Never wear jewelry when working on this equipment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving components causing injury.

FIRE HAZARDS

Keep a fire extinguisher near the generator at all times. Do NOT use any carbon tetra-chloride type extinguisher. Its fumes are toxic, and the liquid can deteriorate wiring insulation. Keep the extinguisher properly charged and be familiar with its use. Consult the local fire department for any questions pertaining to fire extinguishers.

EXPLOSION HAZARDS

Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no combustible materials are left in the generator compartment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surrounding the generator clean and free from debris.

Fuels such as natural gas and LP gas are extremely EXPLOSIVE. Install the fuel supply system according to applicable fuel-gas codes. Before placing the home standby electric system into service, fuel system lines must be properly purged and leak tested according to applicable code. After installation, inspect the fuel system periodically for leaks. No leakage is permitted.

STANDARDS INDEX

In the absence of pertinent standards, codes, regulations and laws, the published information listed below may be used as installation guide for this equipment.

1.NFPA No. 37, STATIONARY COMBUSTION ENGINES AND GAS TURBINES, available from the National Fire Protection Association, 470 Atlantic Avenue, Boston, MA 02210.

2.NFPA No. 76A, ESSENTIAL ELECTRICAL SYSTEMS FOR HEALTH CARE FACILITIES, available same as Item 1.

3.NFPA No. 54, NATIONAL FUEL GAS CODE, available same as Item 1.

4.NFPA No. 58, AMERICAN NATIONAL STANDARD FOR STORAGE AND HANDLING OF LIQUEFIED PETROLEUM GAS, available same as Item 1.

5.NFPA No. 70, NFPA HANDBOOK OF NATIONAL ELECTRIC CODE, available same as Item 1.

6.Article X, NATIONAL BUILDING CODE, available from the American Insurance Association, 85 John Street, New York, N.Y. 10038.

7.AGRICULTURAL WIRING HANDBOOK, available from the Food and Energy Council, 909 University Avenue, Columbia, MO 65201.

8.ASAE EP-3634, INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS, available from the American Society of Agricultural Engineers, 2950 Niles Road, St. Joseph, MI 49085.

9.NFPA No. 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, available same as Item 1.

Carrier 3

Image 5
Contents Parts, Adjustment and Maintenance Manual ‹ Read this Manual Thoroughly IntroductionImportant Safety Instructions General Hazards Electrical Hazards Electrical Checks Check Transfer Switch OperationBefore Initial START-UP Checking Automatic Operation Adjusting the Regulator Natural GAS onlyGenerator Tests Under Load Unit Volts Reconfiguring the Fuel System2 12KW and 15KW, V-TWIN Engines Engine Governor AdjustmentValve Clearance Voltage Regulator AdjustmentValve Clearance Adjustment Problem Cause Correction Troubleshooting GuideBe performed by the nearest Carrier Dealer Service ScheduleElectrical Data Customer Battery Utility SP1 IM1 SP2 IM2 Customer Connection Battery Charge 1VA Electrical Data Electrical Data Electrical Data Electrical Data ATS N2A N1A 51 9 3651 9115 QTY Description Carrier Wire ASSEMBLY, Home StandbySOCKET, 12VDC Accessory CONTROL, Panel Bottom Pull Main ResetCarrier Limit Switch Operation not Shown Transfer Switch Home Standby 100A 2PBOX GTS Load Center COVER, 8 Position GTS Load CenterCarrier COVER, 12 Position GTS Load Center Wire HARNESS,GTS Load Center not Shown for ClarityCOVER, 10 Position GTS Load Center Washer Flat 1/4-M6 ZincCarrier ASSEMBLY, Crankshaft GH410 Small Taper ASSEMBLY, Connecting RODCRANKCASE, Subassembly with Plugs GH410 ASSEMBLY, Governor GearCarrier ASSEMBLY, Plastic Carb HOUSING, BlowerSWITCH, OIL 8.0 PSI ASSEMBLY,GOVERNOR Lever 12 HP1310 ASSEMBLY, Head #1 G&S ASSEMBLY, BreatherASSEMBLY, OIL Fill CAP ASSEMBLY,GOVERNOR Gear122 138 PRE-CLEANER KNOB, AIR CleanerELEMENT, AIR Cleaner Chrome ASSEMBLY, MIXER/AIRBOXCarrier Assembly Brush Holder CABLE, #6 40 Black BatteryBASE, AIR Cleaner ELEMENT, AIR CleanerCarrier Stator 12KW CABLE, #6 48 Black BatteryStator 13KW / 15KW Rotor 12KWAssembly HousingAdjuster SCREW, Twin PIN, Limited AdjustmentCarrier Air-cooled Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators Catalog no AS-PA0 Form ASPAS07-1PD

ASPAS1CCA012, ASPAS1CCA015 specifications

The Carrier ASPAS1CCA015 and ASPAS1CCA012 are advanced air conditioning units designed to offer superior climate control in residential and light commercial settings. Both models reflect Carrier's commitment to innovation, energy efficiency, and user comfort.

One of the primary features of these units is their inverter technology. This smart technology adjusts the compressor speed in real-time, allowing the system to operate efficiently and maintain a consistent temperature. This results in reduced energy consumption and lower utility bills while providing a more comfortable indoor environment.

The ASPAS1CCA015 and ASPAS1CCA012 also include a state-of-the-art air filtration system. These units are equipped with a high-efficiency particulate air (HEPA) filter that effectively captures dust, allergens, and pollutants. This feature contributes to improved indoor air quality, making them ideal for allergy sufferers and those concerned about indoor air pollution.

In terms of performance, both models deliver impressive cooling and heating capacities. The ASPAS1CCA015 has a cooling capacity of 15,000 BTUs, while the ASPAS1CCA012 offers a cooling capacity of 12,000 BTUs. This range makes them suitable for various room sizes, ensuring effective temperature management whether during scorching summers or chilly winters.

A user-friendly digital thermostat and Wi-Fi connectivity are additional features that enhance the usability of these models. Homeowners can control their air conditioning systems remotely via smartphones or tablets, enabling them to adjust settings for optimum comfort and efficiency even when they are not at home.

The units are designed with quiet operation in mind. They utilize advanced silencing technologies, ensuring that noise levels remain low, allowing for peaceful environments during night-time or in quiet settings. This is particularly beneficial for bedrooms, nurseries, or offices where distraction-free air conditioning is essential.

Moreover, both models are compliant with the latest standards for energy efficiency, earning high SEER (Seasonal Energy Efficiency Ratio) ratings. This not only promotes environmental sustainability but also aligns with governmental incentives aimed at reducing energy consumption.

In summary, the Carrier ASPAS1CCA015 and ASPAS1CCA012 are equipped with cutting-edge technologies and features that make them reliable and efficient air conditioning solutions. With their inverter technology, advanced filtration systems, remote connectivity, and quiet operation, these units represent a combination of comfort, convenience, and environmental responsibility that meets the needs of modern users.