Carrier ZC manual Conditioner comes with the two drain holes closed by plugs

Page 17

IMPORTANT

If unit is installed where condensate drainage from the back of the unit can drip onto pedestrians or neighboring property, use the external drain kit supplied with the unit. See installation instructions on drain kit. - Step 9.

Hold tip angle and mark with chalk the location of screw holes to be drilled in each side of the casing for fastening in wall opening.

Drill 3 screw holes in each side of wood frame. Recheck outward tip.

NOTE

Chassis is heavy. Obtain help when lifting to avoid personal injury.

9. DRAIN SYSTEM OPTIONS

The conditioner comes with the two drain holes closed by plugs.

The conditioner is projected to use one of the three function options:

1)No drain connection. That way provides the most efficiency operation, but has splash noise, dripping of rain water or condensate water.

2)Rear drain, which provides a good efficiency for operation and very low splash noise, or

3)Drain pan, which captures the most condensate and does not have splash noise, but has lower efficiency operation. Both the rear drain and the drain pan can be connected to a hose and directed to a convenient location on the ground, or a suitable floor drain.

Install the draining system for the condensing water before positioning the unit in the cabinet. You must use one of the two existing systems, depending on how, and where the unit will be installed.

9.1DRAINING SYSTEM THROUGH THE REAR OUTLET

NOTE

Remove the rear plug from the unit, and install the drain (item 6, page 4).

Pass a 5/8" (15,9 mm) plastic hose through the hole located on the rear of the cabinet.

The hose must be long enough to reach the rain water drain.

17

Image 17
Contents Air Conditioner Owner`s Guide For heat units, the heat is not for primary source of heat Some SuggestionsIndex Receiving the AIR Conditioner For your safety wear glovesNameplate Temperature and Timer adjustment Timer AIR Conditioner with Remote ControlOperating the Electronic Unit with the Remote Control Battery useful life is around one yearTo cool, press the Cooling mode button Only for models with heat featureSpeed can be selected among one of the three existing levels Fan Function only circulates the air in the roomTo save power, press the Energy Saver button Operating Unit from the Control Panel Without the Remote ControlFour way air flow provided by the mobile louvers AIR Direction and Exhaust ControlTips to Achieve Maximum Efficiency and Comfort East, because the sunrays are less intense Free area4 17 cm 12 30 cm THROUGH-THE-WALL InstallationMm lower than the front edge inside room Install Casing in WallHose must be long enough to reach the rain water drain Conditioner comes with the two drain holes closed by plugsDraining System Through the Rear Outlet Other end of the hose must be connected to the water mains Installing the Unit in the Cabinet Install the safety screw on both sidesElectrical Data To test your power supply cord Power Supply CordPress Reset This room air conditioner is equipped with a power supplyDo not allow children to operate the unit Operation with Power OutageCleaning of the Plastic Front and of the Cabinet Internal Cleaning and General Inspection Cleaning of the AIR FilterPractical Solutions Carrier Room Air Conditioner Full Warranty Carrier Corporation Page GW256.08.003 12/06

ZC specifications

The Carrier ZC series represents a step forward in the realm of heating, ventilation, and air conditioning (HVAC) systems. Renowned for its commitment to energy efficiency, reliability, and advanced technology, the Carrier ZC is a standout choice for both residential and commercial applications.

One of the hallmark features of the Carrier ZC is its exceptional energy efficiency. Many models are equipped with variable-speed technology, which allows the system to adjust its output based on the specific heating or cooling demands of the space. This not only optimizes comfort but also significantly reduces energy consumption, making it an eco-friendly and cost-effective option.

In addition to energy efficiency, the Carrier ZC incorporates advanced control technologies. The system can be integrated with smart home technology, allowing users to monitor and control their HVAC systems remotely through smartphones or tablets. Features like Wi-Fi connectivity, scheduled programming, and real-time diagnostic capabilities make the Carrier ZC convenient and user-friendly, ensuring that occupants can maintain their desired comfort levels effortlessly.

The Carrier ZC series also emphasizes air quality and filtration. Many models come equipped with advanced air filtration systems designed to capture allergens and other pollutants from the indoor environment. This focus on air quality is especially beneficial for those with respiratory concerns, as it helps create a healthier living space.

Durability and quiet operation are further characteristics of the Carrier ZC. The units are built using high-quality materials to withstand the rigors of continuous use, and noise-reduction technology helps minimize operational sound. This makes the Carrier ZC ideal for residential environments where maintaining a peaceful atmosphere is essential.

Moreover, the Carrier ZC is versatile in its configurations, offering various options to suit different installation requirements. Whether it’s ducted or ductless systems, the flexibility of design allows for seamless integration into both new builds and retrofits.

In summary, the Carrier ZC series is defined by its energy efficiency, smart technology integration, air quality enhancement, durability, and versatility. These features collectively make it a top contender in the competitive HVAC market, ensuring that users can enjoy superior comfort and savings year-round.