Carrier ZC manual THROUGH-THE-WALL Installation, 4 17 cm 12 30 cm

Page 15

THROUGH-THE-WALL INSTALLATION

NOTE

Window installation GW 05825004 instructions come with the window accessory kit only for ZC models. It is available as an accessory for ZH and ZQ models.

Through-the-wall installation can be made in wood frame or masonry walls. The casing must be tipped to the outside to aid in draining condensate. The installation should be weatherproofed outside and finished inside.Installations in wood framed or masonry walls can be made using the casing as follows. Fasten the casing directly to masonry or studding using masonry or woodscrews. Adjust the outward tip front to rear, so it drops from 3/16 to 3/8-in. (5-10-mm). If wall thickness overlaps the side louver in unit casing,make wall opening wider, as shown in Fig. below. If wall projects beyond back of unit, use baffles onrear corners of casing.

6 3/4(17 cm)

45°

12” (30 cm)

CAUTION

Good framing construction practices must be followed to ensure a safe, secure and properly installed unit.

Cut opening in wall. For dimensions see Fig. below.

Frame opening in wall. For wood framing,provide a wooden framing support or other approved structure for fastening casing to wall. See Fig. for typical wood framing.

WALL STUD

FRAME OR

BACK UP STRIP

 

FINISHED

17 5/16”

OPENING(440mm)

DIMENSIONS

26 3/16” (665mm)

Tipical wood framing

For masonry framing, use a lintel to support wall above opening. Mouting angles are sometimes assembled to casing. Be sure to size the wall opening to provide clearance for metal thickness of casing and mouting angles if they are used. If mounting angles are to be used with casing, position angles as follows:

1.Flush with unfinished wall - plaster over or use decorative molding.

2.Against finished wall - use decorative molding.

3.Inside wall opening - use decorative molding.

15

Image 15
Contents Air Conditioner Owner`s Guide For heat units, the heat is not for primary source of heat Some SuggestionsIndex Receiving the AIR Conditioner For your safety wear glovesNameplate Temperature and Timer adjustment Timer AIR Conditioner with Remote ControlOperating the Electronic Unit with the Remote Control Battery useful life is around one yearTo cool, press the Cooling mode button Only for models with heat featureSpeed can be selected among one of the three existing levels Fan Function only circulates the air in the roomTo save power, press the Energy Saver button Operating Unit from the Control Panel Without the Remote ControlFour way air flow provided by the mobile louvers AIR Direction and Exhaust ControlTips to Achieve Maximum Efficiency and Comfort East, because the sunrays are less intense Free area4 17 cm 12 30 cm THROUGH-THE-WALL InstallationMm lower than the front edge inside room Install Casing in WallConditioner comes with the two drain holes closed by plugs Draining System Through the Rear OutletHose must be long enough to reach the rain water drain Other end of the hose must be connected to the water mains Installing the Unit in the Cabinet Install the safety screw on both sidesElectrical Data This room air conditioner is equipped with a power supply Power Supply CordTo test your power supply cord Press ResetOperation with Power Outage Cleaning of the Plastic Front and of the CabinetDo not allow children to operate the unit Internal Cleaning and General Inspection Cleaning of the AIR FilterPractical Solutions Carrier Room Air Conditioner Full Warranty Carrier Corporation Page GW256.08.003 12/06

ZC specifications

The Carrier ZC series represents a step forward in the realm of heating, ventilation, and air conditioning (HVAC) systems. Renowned for its commitment to energy efficiency, reliability, and advanced technology, the Carrier ZC is a standout choice for both residential and commercial applications.

One of the hallmark features of the Carrier ZC is its exceptional energy efficiency. Many models are equipped with variable-speed technology, which allows the system to adjust its output based on the specific heating or cooling demands of the space. This not only optimizes comfort but also significantly reduces energy consumption, making it an eco-friendly and cost-effective option.

In addition to energy efficiency, the Carrier ZC incorporates advanced control technologies. The system can be integrated with smart home technology, allowing users to monitor and control their HVAC systems remotely through smartphones or tablets. Features like Wi-Fi connectivity, scheduled programming, and real-time diagnostic capabilities make the Carrier ZC convenient and user-friendly, ensuring that occupants can maintain their desired comfort levels effortlessly.

The Carrier ZC series also emphasizes air quality and filtration. Many models come equipped with advanced air filtration systems designed to capture allergens and other pollutants from the indoor environment. This focus on air quality is especially beneficial for those with respiratory concerns, as it helps create a healthier living space.

Durability and quiet operation are further characteristics of the Carrier ZC. The units are built using high-quality materials to withstand the rigors of continuous use, and noise-reduction technology helps minimize operational sound. This makes the Carrier ZC ideal for residential environments where maintaining a peaceful atmosphere is essential.

Moreover, the Carrier ZC is versatile in its configurations, offering various options to suit different installation requirements. Whether it’s ducted or ductless systems, the flexibility of design allows for seamless integration into both new builds and retrofits.

In summary, the Carrier ZC series is defined by its energy efficiency, smart technology integration, air quality enhancement, durability, and versatility. These features collectively make it a top contender in the competitive HVAC market, ensuring that users can enjoy superior comfort and savings year-round.