Black & Decker em100b instruction manual Type 3-ELECTRONIC Withoptical Port on TOP

Page 7

90539499 01 EM100B.qxd 7/7/08 10:05 AM Page 12

03 INSTALLING YOUR METER SENSOR

TYPE 2—ELECTRONIC WITHOPTICAL PORT ON FACE

C. Install Your Meter Sensor

1.Wipe the meter dome clean with the damp cloth.

2.Fit the Meter Sensor over your utility meter as shown, so that the Sensor Head sits as close as possible to the front of the glass dome.

3.Tighten the clamp until the Meter Sensor is snug, but can move just enough to allow for slight adjustments.

4.Position the Sensor Arm as shown to the right:

Note: The LED at the end of the Sensor Arm must be positioned directly over the optical port on the meter.

Note: If your electric meter has two optical ports, align the sensor with the one on the left.

5 . Press the RESET button . The STATUS Indicator will light solid red while the Meter Sensor looks for a signal from the meter.

6 . When you have positioned the Sensor Head correctly, the red STATUS Indicator starts flashing regularly, indicating that the Sensor has detected the signal from your meter. Within one minute, in addition to the regular flashing, you should see an extra flash now and then, depending on your rate of electri c i ty consumption. These extra flashes are normal, and indicate

that the Sensor is reading the mete r’sStatus Light Indicator output correctly.

NOTE: To maximize batte ry life, the indicator stops flashing after about two minutes.

7.Tighten the clamp just enough so that the Meter Sensor cannot move.

Installation is complete! Go to

Section 4.

03 INSTALLING YOUR METER SENSOR

TYPE 3—ELECTRONIC WITHOPTICAL PORT ON TOP

A. Record Your Meter’s Power Factor

Find and record your meter’s Power Factor. On the face of the meter, look for a number preceded by the letters Kh, Ks, or Kt.This number is usually 1.0 for an electronic meter. If your meter lists more than one of these numbers, look for the smallest number. Write this number in the box below.You will need it later (in section 06) when you program your Digital Display.

Optical

 

 

Port

Power Factor =

(usually 1.0 Kh)

Power Factor

B. Prepare Your Meter Sensor

Latch Cover

 

Make sure the batteries are installed in the Meter Sensor.

Clamping

For this type of meter, you need to reconfigure the Sensor.

Strap

1.

Use a flat-head screwdriver to open the clamping strap

 

 

all the way until it opens. Remove the strap from the

 

 

Sensor body.

 

2 .

Pull the Sensor A rm Latch Cover up to unlock

 

 

the arm as shown (2).

 

3 . Pull the Sensor A rm completely out of the body until it is completely detached, connected only by the wire (3). You may need to pull hard .

12

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 7
Contents EM100B Contents Beforeyou Begin Installing Your Meter Sensor Understanding Your Power MonitorType 1-ELECTROMECHANICAL Type 2-ELECTRONIC Withoptical Port on Face Type 3-ELECTRONIC Withoptical Port on TOP Status Reset Indicator Button Synchronizemetersensoranddigitaldisplay Determinebilling Mode and Billing RateFlat Rate Billing Determine Your Billing Rate Flat Rate Billing ExampleExample of a three-tier billing plan Tiered Rate Billing ExampleTime-of-Use Rate Billing Example Determine Billing Mode and Billing RateElectric Bill Program Digital Display TIME, DAY TEMPERATURE, Power FACTOR, BillingmodeYou recorded in section Program Digital Display Flat Rate BillingProgram Digital Display Tiered Ratebilling Program Digital Display TIME-OF-USE Ratebilling Power View Using Your Power MonitorCost View Measure the Consumption of a Single Appliance with Tare We recommend these steps after Power Monitor setupTroubleshooting and Q&A Troubleshooting and Q&A How Electricity is Measured TechnicalspecificationsService Information Howelectricity is MeasuredFull Two-Year Home Use Warranty