Rev. 0505
Humidification
HUMIDIFICATION SYSTEM (WHERE APPLICABLE)
One contributor to spoilage of fresh meat and deli products that are displayed in refrigerated service type merchandisers is dehydration, which causes the product to shrink and dry out. The humidification system is designed to maintain a high relative humidity (RH) inside HussmannÕs refrigerated service type merchandisersÑ and minimize dehydration.
The humidification system is located on the back wall under the rear discharge air grill of the VGM / VGD FAMILY. It is imperative that the system be maintained as per the instructions in the maintenance section. Buildup of residue will cause leakage and/or unfavorable water conditions. If the areaÕs water is hard, check the system more frequently than under good water conditions.
I N S T R U C T I O N S
Turn on water and fans, and check for leaks. This system has been tested at the factory, and should not require any additional adjustments.
The system is constructed almost entirely of PVC pipe, and user air that is
1.Keep the case clean.
2.Keep the water filter clean, and change it every 6- 12 months, depending on the kind of water found in your area.
3.Flush the header every 6 months, by loosening the
1/8" 100 X 1/8FPT
SW ADAPTER
connecting ÒLÓ, remove it from the case, and flushing with a hose.
IMPORTANT INFORMATION
The VGM / VGD case line is easy to work, and capable of maintaining superb product quality with the installation of the proper controlling devices. These should be set according to the HussmannÕs specifications, and a prop- erly maintained humidity system. Incorrect settings and failure to maintain the humidity system will result in short product life. Below are a few guidelines for opti- mum performance and product life:
¥Set thermostat to cut in at
¥Temperatures should be achieved by means of a
¥Clean humidity system a minimum of every 90 days for proper system operation.
¥Work and rotate product - not to exceed a
¥At night, turn off case lights, and cover product with moistened cheese cloth or fabric towels.
¥Keep meat prep room refrigerated at 55¼F.
¥Meat Bloom Box (if applicable ) should be at 30¼F. HUMIDITY SYSTEM as viewed from the front.
NOTE: The axial fans included in the humidity system must be replaced as a unit. Humidity
SPRAY HEADER | 1/4" 100 X 1/8FPT | |||
SW ADAPTER | ||||
RUNS LENGTH OF CASE |
|
| ||
|
|
| 1/4" OD X 1/8" FPT | |
|
|
| SW ADAPTER | |
|
|
| ||
REAR INTERIOR WALL OF CASE |
|
| 1/8" MPT X 1/4" COMP | |
|
| PVC ADAPTER | ||
VIEWED FROM FRONT |
|
| ||
|
| |||
1/4"MPT X 1/4" COMP PVC ADAPTER | ||||
| ||||
|
|
|
| |
WATER |
|
| PAN AND ACCESS PANEL | |
|
|
| ||
SUPPLY |
|
|
|
1/4"MPT X 1/4" OD BALL VALVE WATER FILTER COMP ADAPTER HAMMON 3 STAGE #00015
2ND FAN USED | 3" AXIAL FAN |
IN 12' CASE |
7