Carrier 50JZ 024-060 ICM Fiop Physical Data-Unit 48JZ, Outdoor Coil, Indoor Coil, Indoor Blower

Page 15

Table 4—ICM FIOP Physical Data—Unit 48JZ

THIS DATA APPLIES TO 48JZ UNITS WITH THE ICM INDOOR MOTOR FIOP

UNIT SIZE 48JZ

024040

030040

030060

036060

036090

042060

042090

NOMINAL CAPACITY (ton)

2

2-1/2

2-1/2

3

3

3-1/2

3-1/2

OPERATING WEIGHT (lb.)

310

324

324

321

321

380

380

COMPRESSORS

 

 

 

Scroll

 

 

 

Quantity

 

 

 

1

 

 

 

REFRIGERANT (R-410A)

7.0

8.9

8.9

9.3

9.3

9.5

9.5

Quantity (lb.)

 

 

 

 

 

 

 

REFRIGERANT METERING DEVICE

 

 

 

 

 

 

 

Orifice Indoor (in.)

0.061

0.061

0.061

0.067

0.067

0.073

0.073

AccuRater™ Piston

 

 

 

 

 

 

 

REFRIGERANT METERING DEVICE

 

 

 

 

 

 

 

Orifice Outdoor (in.)

0.032 (2)

0.040 (2)

0.040 (2)

0.040 (2)

0.040 (2)

0.038 (2)

0.038 (2)

AccuRater™ Piston

 

 

 

 

 

 

 

OUTDOOR COIL

2...17

2...17

2...17

2...17

2...17

2...17

2...17

Rows...Fins/in.

8.5

10.3

10.3

10.3

10.3

13.5

13.5

Face Area (sq ft)

 

 

 

 

 

 

 

OUTDOOR FAN

2350

2350

2350

2500

2500

2350

2350

Nominal Cfm

22

22

22

22

22

22

22

Diameter (in.)

1/8 (825)

1/8 (825)

1/8 (825)

1/4 (1100)

1/4 (1100)

1/8 (825)

1/8 (825)

Motor Hp (Rpm)

 

 

 

 

 

 

 

INDOOR COIL

3...15

3...15

3...15

4...15

4...15

3...15

3...15

Rows...Fins/in.

3.7

3.7

3.7

3.7

3.7

4.7

4.7

Face Area (sq ft)

 

 

 

 

 

 

 

INDOOR BLOWER

800

1000

1000

1200

1200

1400

1400

Nominal Airflow (Cfm)

10 X 10

10 X 10

10 X 10

11 X 10

11 X 10

11 X 10

11 X 10

Size (in.)

1/2

1/2

1/2

3/4

3/4

3/4

3/4

Motor (HP)

 

 

 

 

 

 

 

FURNACE SECTION*

 

 

 

 

 

 

 

Burner Orifice No. (Qty...Drill Size)

2...44

2...44

2...38

2...38

3...38

2...38

3...38

Natural Gas

2...50

2...50

2...46

2...46

3...46

2...46

3...46

Burner Orifice No. (Qty...Drill Size)

 

 

 

 

 

 

 

Propane Gas

 

 

 

 

 

 

 

HIGH-PRESSURE SWITCH (psig)

 

 

 

610 ± 15

 

 

 

Cutout

 

 

 

 

 

 

 

 

 

420 ± 25

 

 

 

Reset (Auto)

 

 

 

 

 

 

 

 

 

 

 

 

 

LOSS-OF-CHARGE/LOW-

 

 

 

 

 

 

 

PRESSURE SWITCH

 

 

 

20 ± 5

 

 

 

(Liquid Line) (psig)

 

 

 

 

 

 

 

 

 

45 ± 10

 

 

 

Cutout

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset (Auto)

 

 

 

 

 

 

 

RETURN-AIR FILTERS (in.)

20 X 20 X 1

20 X 20 X 1

20 X 20 X 1

20 X 24 X 1

20 X 24 X 1

24 X 30 X 1

24 X 30 X 1

Throwaway

 

 

 

 

 

 

 

* Based on altitude of 0 to 2000 ft.

15

Image 15
Contents Installation, Start-Up, and Operating Instructions Standard Connection Special Procedures for 208-V OperationEasy SELECT-48GP Control Voltage ConnectionsTime Delay Profile When Thermostat is SET on Continuous FANHigh Airflow Accessory Installation AIR Conditioner48GP Sequence of Operation Select Options Easy SELECT-48JZHumidifier Wiring-48JZ 48JZ Sequence of Operation TionEasy SELECT-50GL & 50JZ Page 50GL & 50JZ Sequence of Operation Humidifier Wiring for 50GL & 50JZFAN Operation ICM Fiop START-UPAutomatic CHANGE-OVER Cooling ModeGAS Heat Mode Heat Pump HeatingICM Fiop Physical Data-Unit 48GP LOSS-OF-CHARGE/LOW-PRESSURE Switch 48GP with ICM Fiop Electrical DataSize 48GP ICM Fiop Electric Schematic-Unit 48GP Indoor Blower ICM Fiop Physical Data-Unit 48JZOutdoor Coil Indoor Coil48JZ with ICM Fiop Electrical Data ICM Fiop Electric Schematic-Unit 48JZ ICM Fiop Physical Data-Unit 50GL Heat Power Supply Size 50GL 50GL with ICM Fiop Electrical DataRange Motor ICM Fiop Electrical Schematic-50GL ICM Fiop Physical Data-Unit 50JZ Compressor Quantity TypeRefrigerant 50JZ with ICM Fiop Electrical Data Range Motor Heat Power Supply Size 50JZICM Fiop Electrical Schematic-50JZ CFM Adjust LO PIN NOM PIN HI PIN Unit PIN Select Size 48GP & 48JZ ICM Air Flow vs. Temperature Rise Chart 48GP & 48JZ Gas Heating ICM Airflow Small Cabinet48GP & 48JZ Gas Heating ICM Airflow Large Cabinet Minimum Airflow for Reliable Electric Heater Operation CFM Filter Pressure Drop Table in. wg Electric Heat Pressure Drop Table in. wgElectric Heat Pressure Drop Table in. wg Large Cabinet ICM Fiop WET Coil Pressure Drop in. wgCause Remedy Troubleshooting ChartPreliminary Information START-UP ChecklistBook Catalog No Form 48-21SI 10-01 Replaces 48-20SI Tab

48JZ (N) 024-060, 50JZ 024-060, 48GP (N) 024-060, 50GL 024-060 specifications

The Carrier 50GL 024-060, 48GP (N) 024-060, 50JZ 024-060, and 48JZ (N) 024-060 units are part of Carrier’s advanced HVAC solutions, offering efficient cooling and heating systems designed for both residential and light commercial applications. These models are known for their reliability, energy efficiency, and innovative technology, making them a popular choice for users looking to enhance comfort while reducing operational costs.

One of the main features of the Carrier 50GL series is its use of high-efficiency compressors. These compressors are engineered to operate quietly and effectively, providing optimal performance even during peak load conditions. Additionally, they are equipped with smart features that allow for precise temperature control and improved energy savings, often exceeding standard performance metrics.

The 48GP (N) units are particularly notable for their compact design, making them ideal for installations where space is a limitation. Despite their smaller footprint, they boast significant cooling and heating capacities, ensuring consistent comfort. The use of advanced variable-speed technology in these units helps to maintain consistent indoor temperatures while minimizing energy consumption.

The 50JZ and 48JZ (N) models incorporate advanced inverter technology, allowing for variable refrigerant flow. This technology adjusts the system's output according to the demand, resulting in lower energy usage and increased comfort levels. Additionally, these units feature enhanced filtration systems that improve indoor air quality by capturing airborne pollutants, allergens, and other contaminants.

Another key characteristic of these Carrier units is their durability. Built with high-quality materials, they are designed to withstand harsh environmental conditions, ensuring longevity and reduced maintenance requirements. Furthermore, the installation process is simplified, thanks to user-friendly design features that promote easy serviceability and accessibility.

Overall, the Carrier 50GL 024-060, 48GP (N) 024-060, 50JZ 024-060, and 48JZ (N) 024-060 HVAC units stand out in the industry for their advanced features, energy efficiency, and robust performance. They offer a comprehensive solution for anyone seeking reliable temperature control and improved indoor air quality in a variety of settings.