Carrier 48GP (N) 024-060 Easy SELECT-48GP, Control Voltage Connections, Standard Connection

Page 2

Approved for outdoor installation on wood flooring or on class A, B or C roof covering materials.

Before performing service or maintenance operations on system, turn off main power to unit and install lock-out tag. Turn off accessory heater power switch if applicable. Elec- trical shock could cause severe injury or death.

Puron® (R-410A) systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on Puron® (R-410A) equipment. Ensure service equipment is rated for Puron® (R-410A)

INTRODUCTION

NOTE: The minimum outdoor cooling operating temperature for units using this ICM motor option is 55°F. To operate in cooling at lower ambients the Motor Master™ II low ambient kit is

Make sure that the power supply to the unit is switched OFF before making any wiring changes. With disconnect switch open, move yellow wire from transformer (3/16 in.) terminal marked 230 to terminal marked 200. This retaps transformer to primary voltage of 208-v. Electrical shock could cause serious injury or death.

EASY SELECT™—48GP

HIGH VOLTAGE

 

POWER LEADS

POWER

(SEE UNIT WIRING

SUPPLY

LABEL)

 

GND

FIELD-SUPPLIED

FUSED DISCONNECT

required.

These instructions cover the installation of a Carrier Small Packaged Product with ICM motor-factory installed option (FIOP). This option can be selected as a FIOP on gas heating/electric cooling (48GP), dual fuel–electric heat pump with gas heat back-up (48JZ), electric cooling (50GL) or electric heat pump (50JZ) units with Puron®.

RECEIVING AND INSTALLATION

Refer to unit Installation Instructions.

CONTROL BOX

 

BLK(DH)

 

YEL(Y)

 

GRN(G)

LOW-VOLTAGE

RED(R)

POWER LEADS

(SEE UNIT

BRN(C)

WIRING LABEL)

 

WHI(W1)

DHUM

Y

G

R

C

W1

THERMOSTAT (TYPICAL)

ICM FIOP PRE-START-UP

Step 1—Electrical Connections

CONTROL VOLTAGE CONNECTIONS

NOTE: Do not use any type of power-stealing thermostat, with- out connecting the C (Common) terminal. Failure to follow this note could result in unit control problems.

Use no. 18 American Wire Gage (AWG) color-coded, insulated (35 C minimum) wires to make the control voltage connections between the thermostat and the unit. If the thermostat is located more than 100 ft from the unit (as measured along the control voltage wires), use no. 16 AWG color-coded, insulated (35 C minimum) wires.

STANDARD CONNECTION

Remove knockout hole located in the heat section panel adjacent to the service access panel (See unit installation package). Remove the rubber grommet from the installer’s packet (included with unit)

SPLICE BOX

LEGEND

Field Control-Voltage Wiring

Field High-Voltage Wiring

C01026

Fig. 2—48GP High- and Control-Voltage

Connections

HIGH VOLTAGE

 

POWER LEADS

POWER

(SEE UNIT WIRING

SUPPLY

LABEL)

 

 

FIELD-SUPPLIED

 

FUSED DISCONNECT

 

GND

and install grommet in the knockout opening. Provide a drip loop before running wire through panel. Run the low-voltage leads from the thermostat, through the inlet hole, and into unit low-voltage splice box. Locate 18-gage wires leaving control box. These low-voltage connection leads can be identified by colors (See Fig. 2, 3, 4 or 5). Ensure the leads are long enough to be routed into the low-voltage splice box (located below right side of control box). Route leads through hole in bottom of control box and make low-voltage connections (See Fig. 2, 3, 4 or 5). Secure all cut wires, so that they do not interfere with operation of unit.

CONTROL BOX

 

 

BLK (DH)

 

WHT(W1)

 

YEL(Y)

LOW-VOLTAGE

GRN(G)

POWER LEADS

(SEE UNIT

RED(R)

WIRING LABEL)

 

BRN(C)

 

ORN(O)

DHUM

W/W1

Y/Y2

G

R

C

O/W2

THERMOSTAT (THERMIDISTAT ™ )

SPECIAL PROCEDURES FOR 208–V OPERATION

SPLICE BOX

FIELD CONTROL - VOLTAGE WIRING

FIELD HIGH - VOLTAGE WIRING

C01107

Fig. 3—48JZ High- and Control-Voltage

Connections

EASY SELECT™ CONFIGURATION TAPS FOR 48GP

Easy Select™ taps are used by the installer to configure a system.

2

Image 2
Contents Installation, Start-Up, and Operating Instructions Control Voltage Connections Special Procedures for 208-V OperationEasy SELECT-48GP Standard ConnectionHigh Airflow Time Delay ProfileWhen Thermostat is SET on Continuous FAN 48GP Sequence of Operation Accessory InstallationAIR Conditioner Easy SELECT-48JZ Select OptionsHumidifier Wiring-48JZ Easy SELECT-50GL & 50JZ 48JZ Sequence of OperationTion Page Humidifier Wiring for 50GL & 50JZ 50GL & 50JZ Sequence of OperationICM Fiop START-UP FAN OperationHeat Pump Heating Cooling ModeGAS Heat Mode Automatic CHANGE-OVERICM Fiop Physical Data-Unit 48GP Size 48GP LOSS-OF-CHARGE/LOW-PRESSURE Switch48GP with ICM Fiop Electrical Data ICM Fiop Electric Schematic-Unit 48GP Indoor Coil ICM Fiop Physical Data-Unit 48JZOutdoor Coil Indoor Blower48JZ with ICM Fiop Electrical Data ICM Fiop Electric Schematic-Unit 48JZ ICM Fiop Physical Data-Unit 50GL Range Motor Heat Power Supply Size 50GL50GL with ICM Fiop Electrical Data ICM Fiop Electrical Schematic-50GL Refrigerant ICM Fiop Physical Data-Unit 50JZCompressor Quantity Type Range Motor Heat Power Supply Size 50JZ 50JZ with ICM Fiop Electrical DataICM Fiop Electrical Schematic-50JZ CFM Adjust LO PIN NOM PIN HI PIN Unit PIN Select Size 48GP & 48JZ Gas Heating ICM Airflow Large Cabinet 48GP & 48JZ ICM Air Flow vs. Temperature Rise Chart48GP & 48JZ Gas Heating ICM Airflow Small Cabinet Minimum Airflow for Reliable Electric Heater Operation CFM ICM Fiop WET Coil Pressure Drop in. wg Electric Heat Pressure Drop Table in. wgElectric Heat Pressure Drop Table in. wg Large Cabinet Filter Pressure Drop Table in. wgTroubleshooting Chart Cause RemedySTART-UP Checklist Preliminary InformationBook Catalog No Form 48-21SI 10-01 Replaces 48-20SI Tab

48JZ (N) 024-060, 50JZ 024-060, 48GP (N) 024-060, 50GL 024-060 specifications

The Carrier 50GL 024-060, 48GP (N) 024-060, 50JZ 024-060, and 48JZ (N) 024-060 units are part of Carrier’s advanced HVAC solutions, offering efficient cooling and heating systems designed for both residential and light commercial applications. These models are known for their reliability, energy efficiency, and innovative technology, making them a popular choice for users looking to enhance comfort while reducing operational costs.

One of the main features of the Carrier 50GL series is its use of high-efficiency compressors. These compressors are engineered to operate quietly and effectively, providing optimal performance even during peak load conditions. Additionally, they are equipped with smart features that allow for precise temperature control and improved energy savings, often exceeding standard performance metrics.

The 48GP (N) units are particularly notable for their compact design, making them ideal for installations where space is a limitation. Despite their smaller footprint, they boast significant cooling and heating capacities, ensuring consistent comfort. The use of advanced variable-speed technology in these units helps to maintain consistent indoor temperatures while minimizing energy consumption.

The 50JZ and 48JZ (N) models incorporate advanced inverter technology, allowing for variable refrigerant flow. This technology adjusts the system's output according to the demand, resulting in lower energy usage and increased comfort levels. Additionally, these units feature enhanced filtration systems that improve indoor air quality by capturing airborne pollutants, allergens, and other contaminants.

Another key characteristic of these Carrier units is their durability. Built with high-quality materials, they are designed to withstand harsh environmental conditions, ensuring longevity and reduced maintenance requirements. Furthermore, the installation process is simplified, thanks to user-friendly design features that promote easy serviceability and accessibility.

Overall, the Carrier 50GL 024-060, 48GP (N) 024-060, 50JZ 024-060, and 48JZ (N) 024-060 HVAC units stand out in the industry for their advanced features, energy efficiency, and robust performance. They offer a comprehensive solution for anyone seeking reliable temperature control and improved indoor air quality in a variety of settings.