Hitachi 308640 manual Operation, Safety, Pressure Relief Procedure

Page 7

Operation

Safety

WARNING

INJECTION HAZARD

Remember, this is not an air spray gun. For your safety be sure to read and follow the Warnings on pages 2 and 3

and throughout the text of this instruction manual.

Keep the wallet sized warning card 179960, pro- vided with the gun, with the operator of this equip- ment at all times. The card contains important treatment information should an injection injury occur. Additional cards are available at no charge from Graco.

Pressure Relief Procedure

WARNING

INJECTION HAZARD

The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid

under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

Dare instructed to relieve the pressure,

Dstop spraying,

Dcheck or service any of the system equipment,

Dor install or clean the spray tip.

1.Lock the spray gun trigger safety to avoid acciden- tally triggering the gun. See Fig. 2.

2.Shut off the power to the pump.

3.Close the bleed-type master air valve (required in the system).

4.Unlock the gun trigger safety.

5.Hold a metal part of the gun firmly to the side of a grounded metal waste container and trigger the gun to relieve the fluid pressure.

6.Lock the gun trigger safety again.

7.Open the pump drain valve (required in the sys- tem) to help relieve fluid pressure in the displace- ment pump. In addition, open the drain valve connected to the fluid pressure gauge (in a system with fluid regulation) to help relieve fluid pressure in the hose and gun. Triggering the gun to relieve pressure may not be sufficient. Have a container ready to catch the drainage.

8.Leave the drain valve(s) open until you are ready to spray again.

9.If you suspect that the spray tip or hose is com- pletely clogged or that pressure has not been fully relieved after following the steps above, very slowly loosen the hose end coupling and relieve pressure gradually, then loosen the coupling completely. Now clear the tip or hose obstruction.

Trigger Safety

Locked or in

ON SAFE Position

Trigger Safety Unlocked or in OFF SAFE Position

05987

Fig. 2

308640 7

Image 7
Contents This manual contains important warnings and information 308640Part No , Series a Part No , Series BTable of Contents Equipment Misuse Hazard T Q InstallationTypical Installation Ventilate the Spray BoothConnect the Fluid Line Connect the Air LineFluid supply container Ground it according to local code Ground the SystemObject being sprayed Ground it according to local code Pressure Relief Procedure SafetyOperation Your application Install a Spray TipHow the Air-Assisted Spray Gun Operates Select a Spray Tip and Air CapRecoil Hazard Adjust the Spray PatternApply the Fluid Check the Diffuser-seat Operation Weekly Clean the Spray Gun and System DailyFlush the Gun Daily 308640 Solution TroubleshootingGeneral Troubleshooting ProblemSpray Pattern Troubleshooting Air Valve Service ServiceFluid Needle Cartridge Service 10b 10a AIR Service NotesPart No , 238852, 238883, PartsDescription Qty Repair KitsDescription Qty 35Y 172479 TAG, instruction not shown 14a 239172 10b 111517 RING, backup Ptfe r 238701238755 NEEDLE, fluid, hi-flow Included with 192096Standard Spray Tips, for use with Air Cap Spray Tip Selection ChartsFluid output at 600 psi 4.1 MPa, 41 bar On the next Measurements, inches mm Gun Dimensions238402 238851 238852 238883 239001 241070 Sound Data Technical DataAccessories Manual changed per ECO Graco Standard WarrantyGraco Phone Number Manual Change Summary