Storage

Cleaning Sprayer Exterior

Wipe paint off outside of sprayer using a soft cloth moist- ened with water or flushing fluid. Use only water-based or oil-based (mineral spirit-type) materials with flash point greater than 100° F (38° C). Do NOT submerge the

sprayer.

ti18879a

Storage

NOTICE

Failure to store sprayer with Pump Armor will result in operational problems the next time you spray. Always circulate Pump Armor through the sprayer after cleaning.

Water or solvents other than mineral spirits left in the sprayer will corrode and damage the pump.

1.Lift prime/spray valve UP to the prime position. Remove material cup and flexible suction tube.

ti16700a

ti18869a ti18870a

2.Remove child-resistent cap. Thread nozzle onto Pump Armor bottle. NOTE: For best results, make sure bottle is full.

ti18067a

3.Hold sprayer upside-down over a waste container.

ti18862a

4.Insert Pump Armor nozzle over material inlet and push firmly until it stops. Squeeze cleaning bottle until Pump Armor flows out drain tube.

ti18066a

ti18177a

 

5.Remove Pump Armor nozzle and replace child-resistent cap and tighten securely for storage.

ti18069a

6.Attach flexible suction tube and material cup. Push valve DOWN to spray position.

ti16701a

ti18872a

ti18871a

7.Recharge battery to full charge before storage. See Charging the Battery, page 6.

8.Store sprayer indoors in a cool, dry place. Store in an upright position only. Never store sprayer with material in the cup.

ti18885a

3A2589D

17

Image 17
Contents Model Charger Cordless Hand-Held Paint Sprayers 3A2589DTable of Contents Fire and Explosion Hazard California Proposition Component Identification Charger Status Indicator Lights Charging the BatterySprayer Status Indicator Light Label Appearance DescriptionTrigger Lock Pressure Relief ProcedurePrime/Spray Valve Trigger LockedReversible Spray Tip Pressure Control Knob Flexible Suction Tube Sprayer Setup If sprayer fails to prime, try one of the steps below Starting a New Job Or Refilling the Material CupChoosing the Correct Tip Choosing Pressure Control Knob SettingUnderstanding Tip Number Selecting Tip Hole SizeTriggering Sprayer Install Spray Tip/Guard Assembly if not installedGetting Started with Basic Techniques Spray Pattern Quality Unclogging Spray Tip/Guard AssemblyAiming Sprayer Flushing Sprayer Shutdown and CleaningTi15529ati19009a Storage Cleaning Sprayer ExteriorWiring General ServiceModels 16M886, 16N657, 24R747 Replacement PartsDescription Parts List Models 16N657, 16M886, 24R747Number Model 16N660 Parts List Model 16N660 Parts List Models 16N660 Installation Inlet Valve Fitting Removal/ServiceRemoval Outlet Valve Fitting RepairProblem Cause Solution TroubleshootingSee Shutdown and Cleaning, Down and Cleaning,Valve Fitting Removal/Service, Removal/Service,Tip/Guard Assembly, Spray Pattern Diagnostics Problem Cause SolutionSee Charging the Battery, See Choosing the Correct Tip,Spray pattern spits at the end Troubleshooting Leaks Metric Technical DataBattery Lithium Ion Date Material Spray Pressure Setting Sprayed Tip Mark Dial Preferred Material Settings LogGraco Information Graco Standard Warranty