Technical Data

Technical Data

Category

Data

Maximum Working Fluid Pressure . . . . . . . . . . . . . . . . . .

Maximum Working Air Pressure . . . . . . . . . . . . . . . . . . . .

Maximum Gun Inlet Air Pressure for HVLP Operation . . .

Maximum Working Fluid Temperature . . . . . . . . . . . . . . .

Fluid Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gun Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

*Sound Pressure at 20 psi (140 kPa, 1.4 bar) . . . . . . . . .

*Sound Pressure at 100 psi (0.7 kPa, 7 bar) . . . . . . . . . .

*Sound Power at 20 psi (140 kPa, 1.4 bar) . . . . . . . . . . .

*Sound Power at 100 psi (0.7 kPa, 7 bar) . . . . . . . . . . . .

Wetted Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model G15: 1500 psi (10 MPa, 105 bar)

Model G40: 4000 psi (28 MPa, 280 bar)

100 psi (0.7 MPa, 7 bar)

14 psi (0.098 MPa, 0.98 bar)

110°F (43°C) 1/4-18 npsm

1/4-18 npsm (R1/4-19) compound male thread 16 oz (450 grams)

66.9dB(A)

80.0dB(A)

76.8dB(A)

89.9dB(A)

Stainless Steel, Carbide, Ultra High Molecular Weight Polyethylene, Engineered Plastic, PTFE, Nylon, Fluoro- elastomer

*All readings were taken with the fan valve fully closed (full fan size), at 20 psi (140 kPa, 1.4 bar) and 100 psi (0.7 kPa, 7 bar), and at the assumed operator position. Sound Power was tested to ISO 9614-2.

 

12

 

10

 

8

Air Flow

6

(SCFM)

 

 

4

 

2

 

0

Air Flow, Standard Air Cap

10.6

8.6

6.4

5.8

4.2

4.6

3.8

2.6

0

10

20

30

40

50

 

 

Gun Inlet Pressure (PSI)

 

 

Fan Valve Open

Fan Valve Closed

3A0149E

39

Image 39
Contents Model G40 Model G40 w/RAC tip Model G15Contents Models Fire and Explosion Hazard Equipment Misuse Hazard Typical Installation Grounding Ventilate the Spray Booth InstallationFluid Line Air LineSetup Reverse-A-CleanRAC Tip Assembly Engageddisengaged Pressure Relief ProcedureOperation Trigger LockSpray Pattern Adjustment How the Air-Assisted Spray Gun OperatesClose Open Hvlp Operation Fluid Application IncorrectCorrect Daily Gun Care, Flushing, and Cleaning General System Maintenance Fluid Filter MaintenanceFlushing and Cleaning TI6729A Engaged Reverse-A-CleanRAC TipDisengaged Disengaged TI6580AProblem Cause Solution TroubleshootingTroubleshooting Complete Gun Packing Repair Fan Valve ReplacementRepair Repair Kits5g* 5c Needle Repair13‡ 14‡ Air Valve Repair Fluid Tube ReplacementRepair 3A0149E Reassembly 5b carbide only Parts Washer Ptfe Part No. Description QtyDescription Description QtyAIR CAP Parts 3A0149E Part No C857, G40 Gun with RAC Tip Ref. No. Part No. Description Qty TIP GUARD/AIR CAP AssyRef. No. Part No. Description GG4 Industrial Spray Tips Spray Tip Selection ChartSpray Tips, for use with G15/G40 Air Cap AAM Fine Finish Spray TipsRAC SwitchTips, for use with G40 RAC Air Cap AAF Fine Finish Pre-Orifice Spray TipsLTX RAC Spray Tips WRX WideRAC Spray Tips FFT Fine Finish RAC Spray TipsAccessories SST Seat Repair Kit Ultimate Gun Cleaning Kit 15C161Fan Valve Fine Adjustment Kit Plastic Seat Repair KitPart Interchangeability Guide Model G40 DimensionsTechnical Data Category Data10.6 Gun Inlet Pressure PSI Graco Information Graco Standard Warranty