Graco 3A0149E important safety instructions Air Line, Fluid Line

Page 7

Air Line

1.Install an air filter (A) on the gun air line to ensure a dry, clean air supply to the gun. Dirt and moisture can ruin the appearance of your finished workpiece. See FIG. 1.

2.Install an air pressure regulator (C) on the gun air line to control air pressure to the gun.

3.Install an air shutoff valve (B) on the gun air line and on the pump air line, to shut off air to the gun.

4.Use a 3/16 in. (5 mm) I.D. or larger air hose to mini- mize excessive pressure drop in the hose.

NOTE: The gun air inlet has a 1/4-18 npsm (R1/4-19) compound male thread that is compatible with NPSM and BSP female swivel connectors.

5.Connect the air hose (G) to the 1/4 npsm gun air inlet. See FIG. 2.

G

TI6556A

FIG. 2

Installation

Fluid Line

Before connecting the fluid line, blow it out with air and flush it with solvent. See Flushing and Clean- ing, page 14. Use solvent which is compatible with the fluid to be sprayed.

If better control of fluid pressure is needed, install a fluid regulator on the fluid line to better control fluid pressure to the gun.

1.Use a fluid filter to remove coarse particles and sed- iment, to avoid clogging the spray tip and causing finishing defects.

NOTE: Guns are equipped with a built-in 100 mesh fluid filter to provide final filtering just before spraying.

2.Connect the fluid hose (F) to the gun fluid inlet. See FIG. 4. If desired, install a fluid swivel connector (189018) at the gun inlet for best maneuverability. See Accessories, page 35.

F

TI6846A

FIG. 4

6.Connect the other end of the air hose (G) to the out- let of the air shutoff valve. See FIG. 3.

B

G

C

A

TI4838A

FIG. 3

3.Connect the other end of the fluid hose (F) to the pump fluid outlet.

3A0149E

7

Image 7
Contents Model G40 Model G40 w/RAC tip Model G15Contents Models Fire and Explosion Hazard Equipment Misuse Hazard Typical Installation Grounding Ventilate the Spray Booth InstallationFluid Line Air LineSetup Reverse-A-CleanRAC Tip Assembly Engageddisengaged Pressure Relief ProcedureOperation Trigger LockHow the Air-Assisted Spray Gun Operates Spray Pattern AdjustmentClose Open Incorrect Hvlp Operation Fluid ApplicationCorrect Daily Gun Care, Flushing, and Cleaning Fluid Filter Maintenance General System MaintenanceFlushing and Cleaning TI6729A Engaged Reverse-A-CleanRAC TipDisengaged Disengaged TI6580AProblem Cause Solution TroubleshootingTroubleshooting Complete Gun Packing Repair Fan Valve ReplacementRepair Repair KitsNeedle Repair 5g* 5c13‡ 14‡ Air Valve Repair Fluid Tube ReplacementRepair 3A0149E Reassembly 5b carbide only Parts Washer Ptfe Part No. Description QtyDescription Qty DescriptionAIR CAP Parts 3A0149E Part No C857, G40 Gun with RAC Tip TIP GUARD/AIR CAP Assy Ref. No. Part No. Description QtyRef. No. Part No. Description GG4 Industrial Spray Tips Spray Tip Selection ChartSpray Tips, for use with G15/G40 Air Cap AAM Fine Finish Spray TipsAAF Fine Finish Pre-Orifice Spray Tips RAC SwitchTips, for use with G40 RAC Air CapLTX RAC Spray Tips WRX WideRAC Spray Tips FFT Fine Finish RAC Spray TipsAccessories SST Seat Repair Kit Ultimate Gun Cleaning Kit 15C161Fan Valve Fine Adjustment Kit Plastic Seat Repair KitPart Interchangeability Guide Model G40 DimensionsCategory Data Technical Data10.6 Gun Inlet Pressure PSI Graco Information Graco Standard Warranty