Graco 3A0156B important safety instructions Setup

Page 9

Setup

1.Standard Units Only: Connect Graco airless hose to sprayer. Tighten securely.

ti14843a

2.Standard Units Only: Connect other end of hose to gun and tighten securely.

Setup

6.Fill throat packing nut with Graco TSL to prevent premature packing wear. Do this each time you spray.

ti13453a

7. Turn power OFF.

ti4265a

ti4265a

ti13031a

3. Engage gun trigger safety.

ti10166a

4. Remove tip guard.

ti2769a

5. Check inlet strainer for clogs and debris.

8.Plug power supply cord into a properly grounded electrical outlet.

ti2810a

9. Turn prime valve down to DRAIN position.

ti14842a

10.Place pump in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to true earth ground. Perform steps 1 - 5 of Startup to flush out storage oil shipped in sprayer. Use water to flush water-base paint and mineral spirits to flush oil-base paint and storage oil.

ti14844a

3A0156B

9

Image 9
Contents 311861 695/795 Premium Hi1095/1595 Premium Hi Ultra MAX lIl ModelsExtension Cords GroundingFire and Explosion Hazard Equipment Misuse Hazard Component Identification Pails Grounding15/20 Amp Switch Pressure Relief ProcedureSetup 15sec StartupSpray Switch Tip InstallationFast Flush WatchDog ProtectionSystem Not Available on All Units To ActivateHose Reel Not Available on All Units Digital Tracking System Not Available on All Units Operation Main MenuCode Number Models Cleanup Pump Armor Technical Data DimensionsLo-Boy Hi-Boy QuikReel 3A0156B Graco Information Graco Standard Warranty