Graco 3A0156B important safety instructions Startup, 15sec

Page 10

Startup

Startup

1. Turn pressure control to lowest pressure.

5.Hold gun against grounded metal flushing pail. Trig- ger gun and increase fluid pressure 1/2 turn. Flush 1 minute.

1/2

ti4271a

ti13243a

2. Turn power ON.

ti4266a

ti4266a

3.Increase pressure 1/2 turn to start motor and allow fluid to circulate through drain tube for 15 seconds; turn pressure down.

15sec.

6.Inspect for leaks. Do not stop leaks with hand or a rag! If leaks occur, perform Pressure Relief Proce- dure, page 8. Tighten fittings. Perform Startup, steps 1 - 5. If no leaks, proceed to step 7.

7.Place pump in paint pail.

ti2714a

PAINT

8.Trigger gun again into flushing pail until paint appears. Move gun to paint pail and trigger for 20 seconds. Set gun safety ON. Assemble tip and guard, see instructions on next page.

1/2

4. Turn prime valve forward to SPRAY position. Disen- gage gun trigger safety.

ti10166a

ti13029a

ti14845a

ti10167a

10

3A0156B

Image 10
Contents 695/795 Premium Hi 3118611095/1595 Premium Hi Models Ultra MAX lIlGrounding Extension CordsFire and Explosion Hazard Equipment Misuse Hazard Component Identification Grounding PailsPressure Relief Procedure 15/20 Amp SwitchSetup Startup 15secSwitch Tip Installation SpraySystem Not Available on All Units WatchDog ProtectionFast Flush To ActivateHose Reel Not Available on All Units Operation Main Menu Digital Tracking System Not Available on All UnitsCode Number Models Cleanup Pump Armor Dimensions Technical DataLo-Boy Hi-Boy QuikReel 3A0156B Graco Standard Warranty Graco Information