Graco 313255K DataTrak Controls and Indicators, Key for FIG, Run Mode, Setup Mode

Page 19

DataTrak Controls and Indicators

DataTrak Controls and Indicators

Key for FIG. 8

AA Runaway Limit, in cycles per minute (user settable;

 

00=OFF)

AB

Lower Displacement (user settable)

AC

Flow Rate Units (user settable to

 

/min, gpm [US], gpm

 

 

 

[Imperial], oz/min [US], oz/min [Imperial], l/min, or cc/min)

AD

LED (fault indicator when lit)

AE

Display

PF

Prime/Flush Key (Enables Prime/Flush mode. While in

 

Prime/Flush mode, runaway protection is disabled and the

 

batch totalizer [BT] will not count.) LED will flash while in

 

Prime/Flush mode.

RK Reset Key (Resets faults. Press and hold for 3 seconds to clear the batch totalizer.) Push to toggle between flow rate and cycle rate. With runaway protection enabled, push to extend and retract the solenoid pin.

CF Cycle/Flow Rate

BT Batch Totalizer

GT Grand Totalizer

RT Runaway Toggle (enable/disable) UT E1 Toggle

DT E2 Toggle

ST E5 Toggle

 

GT

AE, see details at right

Run Mode

RK

PF

ti8622b

CF

BT

RT

AD

ti11883a

Setup Mode

 

UT

 

 

 

 

 

 

 

 

 

 

 

AC

 

 

 

 

 

 

 

 

 

 

 

DT

 

AB

 

 

 

 

 

RK

 

 

 

 

 

PF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ti8623b

 

 

 

AA

 

ST

FIG. 8. DataTrak Controls and Indicators

313255K

19

Image 19
Contents Model G30W82 Model G28C18Ll 2 G c T2 Related Manuals ContentsFire and Explosion Hazard Equipment Misuse Hazard DataTrak has the following agency approvals II 1 G ModelsMerkur 301 Heated Packages G30Wxx and G30Cxx Merkur 281 Heated Packages G28Wxx and G28CxxMerkur 481 Heated Packages G48Wxx Installation Wall Mount Packages Ventilate the Spray BoothGeneral Information Prepare the Operator Prepare the SiteSupplied Components Grounding SetupHose Connections Electrical Housing AccessTrigger Lock Pressure Relief ProcedureFlush Before Using Equipment OperationWet Cup Install the Spray TipPrime the Pump Packages with AA Guns Adjust the AtomizationAdjust the Spray Pattern Packages with Airless Guns No air too little air correct Amount IG . Spray Pattern Problems Follow Pressure Relief Procedure, ShutdownFlush the Pump MaintenancePreventive Maintenance Schedule Tighten Threaded ConnectionsProblem Cause Solution TroubleshootingOperation, Setup Mode, page 20. Bleed Key for FIG DataTrak Controls and IndicatorsRun Mode Setup ModeRunaway Setup ModeRun Mode DataTrak OperationDisplay DiagnosticsPrime/Flush Counter/TotalizerSymbol Code Code Name Diagnosis Cause Diagnostic CodesReplace Battery Replace DataTrak Battery or FuseReplace Fuse Parts Cord Parts 120V Cart Mount Only Non-Hazardous Location ElectricalG40 Gun Description Qty G28xxx ModelsW30CBS G30xxx ModelsDescription Qty G48Wxx ModelsNo. Part No. Description Qty KitsWall Mount Kit 24A578 Heated Cart Mount KitKit 24A581 Pump and Gun Control Panel KitRef. Part Description Qty Kit 24A583 Pump Only Control Panel Kit24B425 DataTrak Ptfe Suction Hose KitsKit Description 24B424Technical Data Wall Bracket Mounting DimensionsGraco Information Graco Standard Warranty