Installation
Supplied Components
See FIG. 1. Components vary by package ordered. See tables on pages 6 to 7. Your package may include:
•The
Trapped air can cause the pump to cycle unexpect- edly, which could result in serious injury from splash- ing or moving parts.
•The pump air regulator (X) controls pump speed and outlet pressure by adjusting the air pressure to the pump.
•The air relief valve (not shown) opens automatically to prevent overpressurization of the pump.
•The gun air regulator (T) adjusts the air pressure to the
•The
•The hose bundle (L) supplies fluid (and air for AA guns) to the gun, and allows recirculation of fluid when the gun is not triggered.
•The gun swivel (J) allows for freer gun movement.
•The suction hose (N) with strainer (P) allows the pump to draw fluid from a 5 gallon (19 liter) pail.
•A fluid filter (F) with a 60 mesh (250 micron) stain- less steel element filters particles from fluid as it leaves the pump.
•DataTrak (V) provides pump diagnostics and mate- rial usage information. See page 19.
•The back pressure regulator (E) controls pressure back to the gun and maintains proper circulation pressure.
•The
•A fluid drain valve (G) relieves fluid pressure in the hose and gun.
•The fluid heater (D) heats the fluid as it passes through, to maintain the correct spraying viscosity.
Read and understand all instructions in the supplied heater manual 309524 before operating the heater.
Heat causes fluid to expand. If the heated fluid is trapped with nowhere to expand, it can cause compo- nent rupture. Be sure to keep the heated fluid circulat- ing (turn the
10 | 313255K |