DataTrak Operation
Replace DataTrak Battery or Fuse
The battery and fuse must be replaced in a
Use only the following approved replacement batter- ies. Use of an unapproved battery will void Graco’s warranty and FM and Ex approvals.
•Ultralife lithium # U9VL
•Duracell alkaline # MN1604
•Energizer alkaline # 522
•Varta alkaline # 4922
Use only a
Replace Battery
1.Unscrew cable from the back of the reed switch assembly. See FIG. 10.
2.Remove the cable from the two cable clips.
ti11992a
FIG. 10. Disconnect DataTrak
3.Remove DataTrak module from bracket. See FIG. 11. Take module and attached cable to a
ti11884a
FIG. 11. Remove DataTrak
4.Remove two screws on back of module to access battery.
5.Disconnect the used battery and replace with an approved battery. See FIG. 12.
Replace Fuse
1.Remove the screw, metal strap, and plastic holder.
2.Pull the fuse away from the board.
3.Replace with a new fuse.
Solenoid Cable
Connection
Fuse
Sensor Cable
Connection
Battery
ti11994a
FIG. 12. DataTrak Battery and Fuse Location
313255K | 23 |