Graco 313255K Replace DataTrak Battery or Fuse, Replace Battery, Replace Fuse

Page 23

DataTrak Operation

Replace DataTrak Battery or Fuse

The battery and fuse must be replaced in a non-hazardous location.

Use only the following approved replacement batter- ies. Use of an unapproved battery will void Graco’s warranty and FM and Ex approvals.

Ultralife lithium # U9VL

Duracell alkaline # MN1604

Energizer alkaline # 522

Varta alkaline # 4922

Use only a Graco-approved replacement fuse. Order Part 24C580.

Replace Battery

1.Unscrew cable from the back of the reed switch assembly. See FIG. 10.

2.Remove the cable from the two cable clips.

ti11992a

FIG. 10. Disconnect DataTrak

3.Remove DataTrak module from bracket. See FIG. 11. Take module and attached cable to a non-haz- ardous location.

ti11884a

FIG. 11. Remove DataTrak

4.Remove two screws on back of module to access battery.

5.Disconnect the used battery and replace with an approved battery. See FIG. 12.

Replace Fuse

1.Remove the screw, metal strap, and plastic holder.

2.Pull the fuse away from the board.

3.Replace with a new fuse.

Solenoid Cable

Connection

Fuse

Sensor Cable

Connection

Battery

ti11994a

FIG. 12. DataTrak Battery and Fuse Location

313255K

23

Image 23
Contents Ll 2 G c T2 Model G28C18Model G30W82 Related Manuals ContentsFire and Explosion Hazard Equipment Misuse Hazard DataTrak has the following agency approvals II 1 G ModelsMerkur 301 Heated Packages G30Wxx and G30Cxx Merkur 281 Heated Packages G28Wxx and G28CxxMerkur 481 Heated Packages G48Wxx Installation Wall Mount Packages Ventilate the Spray BoothGeneral Information Prepare the Operator Prepare the SiteSupplied Components Grounding SetupHose Connections Electrical Housing AccessTrigger Lock Pressure Relief ProcedureFlush Before Using Equipment OperationPrime the Pump Install the Spray TipWet Cup Packages with AA Guns Adjust the AtomizationAdjust the Spray Pattern Packages with Airless GunsNo air too little air correct Amount IG . Spray Pattern ProblemsFollow Pressure Relief Procedure, ShutdownFlush the Pump MaintenancePreventive Maintenance Schedule Tighten Threaded ConnectionsOperation, Setup Mode, page 20. Bleed TroubleshootingProblem Cause Solution Key for FIG DataTrak Controls and IndicatorsRun Mode Setup Mode Runaway Setup Mode Run Mode DataTrak OperationDisplay DiagnosticsPrime/Flush Counter/TotalizerSymbol Code Code Name Diagnosis Cause Diagnostic CodesReplace Fuse Replace DataTrak Battery or FuseReplace Battery Parts G40 Gun Non-Hazardous Location ElectricalCord Parts 120V Cart Mount Only Description Qty G28xxx ModelsW30CBS G30xxx ModelsDescription Qty G48Wxx ModelsNo. Part No. Description Qty KitsWall Mount Kit 24A578 Heated Cart Mount KitRef. Part Description Qty Pump and Gun Control Panel KitKit 24A581 Kit 24A583 Pump Only Control Panel Kit24B425 DataTrak Ptfe Suction Hose KitsKit Description 24B424Technical Data Wall Bracket Mounting DimensionsGraco Information Graco Standard Warranty