Carrier 40RU manual U a a 2 5 a 1 a 6 0 a 0 a

Page 11

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

4 0 R U A A 2 5 A 1 A 6 – 0 A 0 A 0

_____________

____

 

 

 

 

 

 

 

 

 

 

 

Model Type

 

 

 

 

 

 

 

 

 

 

 

 

 

Brand / Packaging

 

40RU = Carrier Fan Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = Standard

 

Puronr R–410ARefrigerant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not Used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = Place Holder

 

A = StandardDXCoil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service Options

 

Q = Heat Pump

 

 

 

 

 

 

 

 

 

 

 

S = Chilled Water Coil

 

 

 

 

 

 

 

 

 

 

0 = Non-Painted Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

1 = Painted Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = None

 

 

 

 

 

 

 

 

 

Not Used

 

 

 

 

 

 

 

 

 

 

 

 

A = Place Holder

 

Nominal Tonnage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 = 20 Tons

 

 

 

 

 

 

 

 

Not Used

 

28 = 25 Tons

 

 

 

 

 

 

 

 

0 = Place Holder

 

30 = 30 Tons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Design Rev

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not Used

 

 

 

 

 

 

 

– = Catalog Model Number

 

A = Place Holder

 

 

 

 

 

 

 

1 = Design Revision (original)

 

Indoor Fan Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

1 = Fan Drive and Motor - Low / Motor Efficiency - Standard

 

 

1 = 575/3/60

 

 

 

 

2 = Fan Drive and Motor - Med / Motor Efficiency - Standard

 

 

5 = 208/230/3/60

 

 

 

3 = Fan Drive and Motor - High / Motor Efficiency - Standard

 

 

6 = 460/3/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = Al/Cu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40RU

Fig. 3 - Model Number Nomenclature

C!0724

POSITION NUMBER

 

1

 

2

3

4

 

5

 

6

 

7

 

8

9

10

TYPICAL

 

2

 

6

1

0

 

G

 

1

 

2

 

3

4

5

 

POSITION

 

 

 

 

 

DESIGNATES

 

 

 

 

 

 

 

1−2

 

 

 

Week of manufacture (fiscal calendar)

 

 

 

 

 

3−4

 

 

 

Year of manufacture (“10” = 2010)

 

 

 

 

5

 

 

 

Manufacturing location (G = ETP, Texas, USA)

 

 

 

 

6−10

 

 

 

 

Sequential number

 

 

 

 

 

Fig. 4 - Serial Number Nomenclature

C!0725

TXV

COIL

horizontal arrangement with return air entering horizontally and the supply air discharging horizontally. When applying the unit in a horizontal arrangement, ensure the condensate drain pan is located at the bottom center of the unit for adequate condensate disposal. See Fig. 6 for condensate connections for each unit position.

REMOVE FOAM BLOCK

PLUG

PLUG

CONDENSATE

DRAIN

LEGEND

TXV — Thermostatic Expansion Valve

C10683

Fig. 5 - Foam Block Location

Unit Positioning - The unit can be mounted on the floor for vertical application with return air entering the face of the unit and supply air discharging vertically through the top of the unit. The unit can also be applied in a

LEGEND

Accessory Line

Alternate Air Intake and Discharge

Air Intake and Discharge

Note: Maintain recommended clearances per Fig. 1 and Fig. 2

C10684

Fig. 6 - Typical Unit Positioning

11

Image 11
Contents Installation, Start---Up Service Instructions PRE-INSTALLATION 40RUA Physical Data, English Cooling Units 40RUA Physical Data, SI Cooling Units Unit 40RUQ 40RUQ Physical Data, English Heat Pump Units138 40RUA Physical Data, SI Heat Pump UnitsOperating charge kg Fins/m 591Chilled Water Coil 40RUS Physical Data, English Chilled Water UnitsUnit 40RUS Max Working Pressure kPag at 125 C Operating Weight kg Base Unit40RUS Physical Data, SI Chilled Water Units Face Area sq m Upper Face Area sq m Lower Rows...Fins/m40RUS*25 Unit Unit Weight40RUA*25 40RUQ*2540RUA*28 1050 40RUA*30 1062 40RUS*28 1035 40RUS*30 1042 Dimensions Sizes 28U a a 2 5 a 1 a 6 0 a 0 a Preferred Suspension Technique Refrigerant and Chilled Water Piping Access Holes Face-Split Coil Suction and Liquid Line Piping Typical Feeder Tubes PER Distributor Factory-Installed Nozzle and Distributor DataFitting Requirements Unit Coil Type TXV Distributor STD40RUA*28 Fitting RequirementTypical 40RUS Chilled Water Piping Condensate Drains Fire Hazard Electrical Data, Alternate Motors Electrical Data, Standard Motors25, 28 Unit Voltage Maximum40RU Holding VATypical Fan Discharge Connections for Multiple Fan Units 40RUA and 40RUQ only Label, TXV AdjustmentManufacturer Lubricant Lubricant DataFan Pulley Alignment Align as follows Fan RotationRemove Filter Retainer Clip Fan Motor Data, Alternate Motor English Fan Motor Data, Standard Motor EnglishFan Motor Data, Alternate Motor SI Fan Motor Data, Standard Motor SIFAN Drive Standard Drive Data, 60 Hz EnglishMedium-Static Drive Data, 60 Hz English Motor DriveStandard Drive Data, 60 Hz SI High-Static Drive Data, 60 Hz EnglishHigh-Static Drive Data, 60 Hz SI Medium-Static Drive Data, 60 Hz SIUnit External Static Pressure kPa 000 542 577 1042 646 716 785 849 907 2830 10.77 11.94 13.08 1087 14.15 15.12 Unit Airflow Pressure Drop FACTORY-SUPPLIED Pressure Drop English40RU Catalog No 40RU---07SI 40RUA, 40RUQ START-UP ChecklistComp A1 Comp B1 Check Voltage Imbalance

40RU specifications

The Carrier 40RU is a highly regarded solution in the realm of commercial cooling systems, specifically designed for applications requiring reliable, long-lasting climate control. This unit stands out due to its engineering excellence, innovative features, and efficient operation.

One of the primary attributes of the Carrier 40RU is its robust construction. Engineered to withstand varying environmental conditions, this unit is built with high-quality materials that promote durability and longevity. The design incorporates corrosion-resistant finishes, which enhances its resilience, especially in outdoor installations.

The Carrier 40RU is equipped with advanced cooling technologies, including variable speed compressors and innovative coil designs. These technologies contribute to its exceptional energy efficiency, allowing the unit to optimize performance while minimizing energy consumption. The variable speed compressors adjust their output based on the current cooling demand, which not only saves energy but also reduces wear and tear on the equipment.

Additionally, the system features a sophisticated control platform that allows for ease of operation and monitoring. This control system offers numerous settings and modes, enabling users to customize their cooling experience based on specific needs. Integration with smart building systems is also possible, providing even greater flexibility and energy management capabilities.

The 40RU model includes a comprehensive filtration system that enhances indoor air quality by effectively capturing dust, allergens, and other particulates. This feature is essential for commercial spaces where maintaining a clean and healthy environment is paramount.

In terms of performance metrics, the Carrier 40RU offers impressive cooling capacities suitable for various applications, from small offices to large commercial buildings. Its noise levels are also minimized through the application of advanced acoustic insulation, ensuring a comfortable environment for occupants.

Moreover, the Carrier 40RU is designed with ease of maintenance in mind. Regular service points are readily accessible, allowing technicians to perform routine checks and repairs efficiently. This design consideration is crucial for minimizing downtime and ensuring the system operates optimally.

In summary, the Carrier 40RU combines rugged construction, energy-efficient technologies, advanced controls, and superior filtration to deliver an outstanding cooling solution for commercial applications. Its versatility, coupled with robust performance characteristics, makes it a preferred choice among HVAC professionals and building managers alike. Whether for new installations or upgrades, the 40RU ensures reliability and comfort in any environment.