Graco Inc 288554, 311053E, 288048 important safety instructions Daily Gun Care

Page 12

Daily Gun Care

Daily Gun Care

CAUTION

Methylene chloride with formic or propionic acid is not recommended as a flushing or cleaning solvent with this gun as it will damage aluminum and nylon compo- nents.

CAUTION

Solvent left in gun air passages could result in a poor quality paint finish. Do not use any cleaning method which may allow solvent into the gun air passages.

Do not point the gun up while cleaning it.

Do not wipe the gun with a cloth soaked in solvent; ring out the excess.

TI8100a

TI4827a

Do not immerse the gun in solvent.

TI8101a

12

311053E

Image 12
Contents Automatic Airless Spray Guns Model 288048 ShownContents Related ManualsEquipment Misuse Hazard Pressurized Equipment Hazard Installation Ventilate Spray BoothConfigure Gun and Manifold Non-circulating SystemInstall Air Fittings Ground SystemMount Gun Reciprocating Arm Rod MountStationary Support Mount All ManifoldsSetup Manifolds 288219 KEYInstall Spray Tip Adjust Spray PatternAdjust a Streaming Tip Flush Spray GunPressure Relief Procedure OperationApply the Fluid IncorrectDaily Gun Care General System Maintenance Daily Cleaning ProcedureDaily Flushing Procedure Perform Pressure Relief Procedure,Troubleshooting General TroubleshootingProblem Cause Solution Problem Cause Solution Spray Pattern Troubleshooting Service DisassemblyService Notes Reassembly Parts Model11† Ref. only Tion Charts, PartsPart No. Description Qty TIP see GG0 Series Tip SelecDescription Qty North America and International ManifoldGG0 Series Tip Selection Charts GG0 Series Spray TipsSealer Application Tip and Air Cap Selection Charts Shower TipStreaming Tips Single Orifice Fan Pattern Spray TipsAccessories Dimensions Mounting Hole Layout Manifold Mounting Hole LayoutTechnical Data Sound Power Levels dBaTriggering Speed Sound Pressure Levels dBaGraco Standard Warranty Graco Information