Installation
Install Air Fittings
1.Install 1/4 in. tube fitting into the cylinder (CYL) air port.
2.Install plugs into the atomization (ATOM) air port and the fan (FAN) air port.
CYL
ATOM
FANTI8225a
FIG. 2: Air Fittings
Ground System
The following grounding instructions are minimum requirements for a system. Your system may include other equipment or objects that must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Your system must be connected to a true earth ground.
Ground Pump
Ground the pump by connecting a ground wire and clamp between the fluid supply and a true earth ground as instructed in your separate pump instruction manual.
Ground Air Compressors and Hydraulic Power Supplies
Ground them according to the manufacturer recommen- dations.
Ground Air, Fluid, and Hydraulic Hoses Connected to Pump
Use only electrically conductive hoses with a maximum of 100 ft (30.5 m) combined hose length to ensure grounding continuity. Check the electrical resistance of your air and fluid hoses at least once a week. If the total resistance to ground exceeds 25 megohms, replace the hose immediately.
Use a meter that is capable of measuring resis- tance at this level.
Ground Spray Gun
Ground the spray gun by connecting it to a properly grounded fluid hose and pump.
Ground Fluid Supply Container
Ground the fluid supply container according to local code.
Ground Object Being Sprayed
Ground the object being sprayed according to local code.
Ground Solvent Pails
Ground all solvent pails that are used with flushing according to local code. Use only metal pails, which are conductive. Do not place the pail on a
6 | 311053E |