Graco Inc 309410 manual WatchDogt Pump Protection System, To Activate 1. Do Startup, Volume

Page 14
WatchDogt Pump Protection System

WatchDogt Pump Protection System

Pump stops automatically when material pail is empty.

To Activate:

1.Do Startup.

Increase pressure to more than 2000 psi (140 bar, 14 MPa).

Note: Instructions to automatically activate the WatchDog pump protection system every time you spray are on page 16.

2. Press and hold DTS button, release when ON is displayed.

Note: GAL (or LITER) flashes while pump protection system is active.

EMPTY displays and the pump stops when pump protection system detects an empty material pail.

3. Turn pump switch OFF to resume normal operation.

Change Display Units:

Pressure:

1. Decrease pressure to less than 200 psi (14 bar, 1.4 MPa)

2.Press and hold (5 seconds) DTS button to change pressure units (psi, bar, MPa), to desired units.

Volume:

1. Enter Life Material Counter mode.

2.Press and hold (5 seconds) DTS button to change volume units (GAL, LITERX10).

14309410

Image 14
Contents 309410 Rev. B S Controls S Setup S StartupS Cleanup S Pressure Relief S Error Codes 233709MISE EN GARDE à la pression maximale de service du systèmeADVERTÊNCIA ADVERTENCIA309410 Trigger Lock Fecho do gatilho Loquet de sécurité Seguro del gatilloContractor CONTROLS / CONTROLES / COMMANDES / CONTROLES4. Install motor drop in and push forward Setup1. Disconnect engine power cord 2. Release tension bar Change Engine to MotorEngage 7. Plug in pressure control power cord6. Secure motor with tension bar 2. Connect other end of hose to gun 3. Tighten securely 4. Remove tip guardDo this each time you spray and store 5. Install clean inlet strainer6. Fill throat packing nut with TSL to prevent premature packing wear cold 8. Fill fuel tank 9. Ground sprayer with grounding clamp2. Turn prime valve down Turn pressure control to lowest pressure 3. Set pump switch OFFStartup PAINT FLUSHa b c d e f g c. Set throttle to fast d. Set engine switch ON e. Pull starter cordg. Set throttle to desired setting 4. Start engine a. Move fuel valve to open b. Move choke to closedDo not stop leaks with your hand or a rag! If 2. Insert SwitchTipt Insert seat and OneSealt SwitchTip and Guard Assembly1. Engage trigger safety seat SwitchTip2. Start engine or motor, page Digital Tracking Systemt DTS Operation1. Do Startup steps 1 Main MenuDigital Tracking System DTS To Activate 1. Do Startup VolumeWatchDogt Pump Protection System Change Display Units Pressure1. Do Startup steps 1. - 3. Pressure must be at zero 3. Simultaneously press DTS button and set pump on/off switch onResettable Hour Meter appears 2. Start engine or motor, page 9. Pressure display appears4. Press and hold to reset to zero, or 11. Short press to return to step 12. Turn pump switch OFF at any time to exit stored data mode9. Short press DTS button again to move to WatchDog MAN manual mode Spray Test Pattern Clearing Tip Clogs2. Turn pressure to lowest setting. Trigger gun to relieve pressure Cleanup1. Set pump switch OFF. Turn engine or motor OFF 3. Turn prime valve down 4. Remove guard and SwitchTip6. Clean filter, guard and SwitchTip in flushing fluid 8. Turn engine ON and start engine or motor. Set pump switch ON 13. Raise siphon tube above flushing fluid and run sprayer for 15 to 30 seconds to drain fluid. Turn pump switch OFF. Turn engine or motor OFF 309409 DTS Error CodesService Graco Phone Number Graco WarrantyADDITIONAL WARRANTY COVERAGE FOR GRACO CANADA CUSTOMERS