Graco Inc 309410 manual Spray Test Pattern, Clearing Tip Clogs

Page 18
Spray Test Pattern

Spray Test Pattern

1. Trigger gun and spray test pattern. Slowly adjust pressure to eliminate heavy edges. Use smaller tip size if pressure adjustment can not eliminate heavy edges.

heavy edges

2. Hold gun perpendicular, 10–12 in. (25–30 cm) from surface. Spray back and forth. Use strokes overlapped by 50%. Start gun movement before trig- gering gun and release trigger before stopping gun movement.

Clearing Tip Clogs

1. Release trigger, put trigger safety ON. Rotate SwitchTip. Take trigger safety OFF and trigger gun to clear the clog.

Clearing Tip Clogs Never point gun towards your hand or into a rag!

2. Put trigger safety ON, return SwitchTip to original position, take trigger safety OFF and continue spraying.

18309410

Image 18
Contents 309410 Rev. B S Controls S Setup S StartupS Cleanup S Pressure Relief S Error Codes 233709MISE EN GARDE à la pression maximale de service du systèmeADVERTÊNCIA ADVERTENCIA309410 Trigger Lock Fecho do gatilho Loquet de sécurité Seguro del gatilloContractor CONTROLS / CONTROLES / COMMANDES / CONTROLES4. Install motor drop in and push forward Setup1. Disconnect engine power cord 2. Release tension bar Change Engine to Motor7. Plug in pressure control power cord 6. Secure motor with tension barEngage 2. Connect other end of hose to gun 3. Tighten securely 4. Remove tip guardDo this each time you spray and store 5. Install clean inlet strainer6. Fill throat packing nut with TSL to prevent premature packing wear cold 8. Fill fuel tank 9. Ground sprayer with grounding clamp2. Turn prime valve down Turn pressure control to lowest pressure 3. Set pump switch OFFStartup PAINT FLUSHa b c d e f g c. Set throttle to fast d. Set engine switch ON e. Pull starter cordg. Set throttle to desired setting 4. Start engine a. Move fuel valve to open b. Move choke to closedDo not stop leaks with your hand or a rag! If 2. Insert SwitchTipt Insert seat and OneSealt SwitchTip and Guard Assembly1. Engage trigger safety seat SwitchTip2. Start engine or motor, page Digital Tracking Systemt DTS Operation1. Do Startup steps 1 Main MenuDigital Tracking System DTS To Activate 1. Do Startup VolumeWatchDogt Pump Protection System Change Display Units Pressure1. Do Startup steps 1. - 3. Pressure must be at zero 3. Simultaneously press DTS button and set pump on/off switch onResettable Hour Meter appears 2. Start engine or motor, page 9. Pressure display appears4. Press and hold to reset to zero, or 12. Turn pump switch OFF at any time to exit stored data mode 9. Short press DTS button again to move to WatchDog MAN manual mode11. Short press to return to step Spray Test Pattern Clearing Tip Clogs2. Turn pressure to lowest setting. Trigger gun to relieve pressure Cleanup1. Set pump switch OFF. Turn engine or motor OFF 3. Turn prime valve down 4. Remove guard and SwitchTip6. Clean filter, guard and SwitchTip in flushing fluid 8. Turn engine ON and start engine or motor. Set pump switch ON 13. Raise siphon tube above flushing fluid and run sprayer for 15 to 30 seconds to drain fluid. Turn pump switch OFF. Turn engine or motor OFF DTS Error Codes Service309409 Graco Phone Number Graco WarrantyADDITIONAL WARRANTY COVERAGE FOR GRACO CANADA CUSTOMERS