Graco Inc G28C18, 313255F, G30W82 DataTrak Operation, Setup Mode, Run Mode, Runaway

Page 20

DataTrak Operation

DataTrak Operation

NOTE: The display (AE) will turn off after 1 minute to save battery life. Press any key to wake up the display.

NOTICE

To prevent damage to the soft key buttons, do not press the buttons with sharp objects such as pens, plastic cards, or fingernails.

Setup Mode

1.See FIG. 8. Press and hold for 5 seconds until Setup menu appears.

2.To enter settings for runaway (if equipped), lower size, and flow rate units, and to enable runaway, E1,

E2, and E5 error options, press to change the

value, then to save the value and move the cur- sor to the next data field. See page 22 for a descrip- tion of E1, E2, and E5 error codes.

NOTE: Graco recommends setting runaway (if

equipped) to 60 .

NOTE: When runaway, E1, E2, and E5 error options are enabled, a will appear on the setup screen.

See FIG. 8.

3.Move the cursor to the E5 error enable option field,

then press once more to exit Setup mode.

Run Mode

Runaway

NOTE: DataTrak is available with and without runaway protection. Packages with M02xxx air motors ship with- out a runaway solenoid. All other DataTrak packages are equipped with a runaway solenoid.

1.See FIG. 8. If pump runaway occurs, the runaway solenoid will actuate, stopping the pump. The LED (AD) will flash and the display (AE) will indicate a runaway condition (see Table 1). The display will cycle through six instruction screens.

2.Runaway Screens 1 and 2: To reset the runaway solenoid, close the master air valve (E). Wait for air to completely bleed off the air motor.

3.Runaway Screens 3 and 4: After the air is bled off, push the solenoid release button (J) down to reset the air valve. The button will pop back up when the air valve is repressurized.

J

ti11902a

FIG. 9. Solenoid Release Button

4.Runaway Screens 5 and 6: Press to clear the diagnostic code and reset the runaway solenoid.

5. Open master air valve (E) to restart pump.

NOTE: To disable runaway monitoring, go to setup mode and set runaway value to 0 (zero) or toggle (RT)

off (see FIG. 8).

20

313255F

Image 20
Contents Model G28C18 G30W82 Ll 2 G c T2Contents Related ManualsFire and Explosion Hazard Equipment Misuse Hazard Models DataTrak has the following agency approvals II 1 GMerkur 281 Heated Packages G28Wxx and G28Cxx Merkur 301 Heated Packages G30Wxx and G30CxxMerkur 481 Heated Packages G48Wxx Installation Ventilate the Spray Booth General InformationPrepare the Operator Prepare the Site Wall Mount PackagesSupplied Components Setup GroundingElectrical Housing Access Hose ConnectionsPressure Relief Procedure Flush Before Using EquipmentOperation Trigger LockPrime the Pump Install the Spray TipWet Cup Adjust the Atomization Adjust the Spray PatternPackages with Airless Guns Packages with AA GunsIG . Spray Pattern Problems Follow Pressure Relief Procedure,Shutdown No air too little air correct Amount Maintenance Preventive Maintenance Schedule Tighten Threaded Connections Flush the PumpTroubleshooting Problem Cause SolutionDataTrak Controls and Indicators Run ModeSetup Mode Key for FIGSetup Mode Run ModeDataTrak Operation RunawayDiagnostics Prime/FlushCounter/Totalizer DisplayDiagnostic Codes Symbol Code Code Name Diagnosis CauseReplace Fuse Replace DataTrak Battery or FuseReplace Battery Parts G40 Gun Shown G28xxx Models Description QtyG30xxx Models W30CBSG48Wxx Models Description QtyKits Wall Mount Kit 24A578Heated Cart Mount Kit No. Part No. Description QtyRef. Part Description Qty Pump and Gun Control Panel KitKit 24A581 Pump Only Control Panel Kit Kit 24A583DataTrak Kits Ptfe Suction Hose KitsKit 24A576 with Runaway Protection Kit 24C580Wall Bracket Mounting Dimensions Technical DataGraco Standard Warranty Graco Information