Grounding

The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit.

1.Pump: See FIG. 2. Verify that the ground screw (GS) is attached and tightened securely to the air motor. Connect the other end of the ground wire (R) to a true earth ground.

R

GS

ti12914a

FIG. 2. Ground screw and wire

2.Pump fluid hoses: use only electrically conductive fluid hoses Check electrical resistance of hoses. If total resistance to ground exceeds 25 megohms, replace hose immediately.

3.Viscon HP Heater: refer to the heater manual, supplied.

4.Air compressor: follow manufacturer's recommen- dations.

5.Spray gun: ground through connection to a properly grounded fluid hose and pump.

6.Fluid supply container: follow your local code.

7.Object being sprayed: follow your local code.

Installation

8.Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or card- board, which interrupts the grounding continuity.

9.To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

Setup

The Viscon HP Heater must be installed by a quali- fied electrician in compliance with all state and local codes and regulations.

Wall Mount Electrical Connections. Follow all directions and requirements in the Viscon HP Heater manual 309524.

Cart Mount Hazardous Location Wiring. The heater is shipped with a fitting that is suitable for wiring in hazardous locations. Follow all directions and requirements in the Viscon HP Heater manual 309524. Do not use the supplied electrical cord, which is suitable only for non-hazardous location wiring.

Cart Mount Non-Hazardous Location Wiring. See FIG. 3. Replace installed fitting with bushing (80), shipped loose. Attach strain relief bushing (79). Follow all directions in the Viscon HP Heater manual 309524 to connect the 120V supplied electrical cord (78), or user-supplied cord for 240V applications.

80

79

78

(120V only)

ti13261a

FIG. 3. Non-Hazardous Location Electrical Cord

313255F

11

Image 11
Contents Ll 2 G c T2 Model G28C18 G30W82Related Manuals ContentsFire and Explosion Hazard Equipment Misuse Hazard DataTrak has the following agency approvals II 1 G ModelsMerkur 301 Heated Packages G30Wxx and G30Cxx Merkur 281 Heated Packages G28Wxx and G28CxxMerkur 481 Heated Packages G48Wxx Installation Wall Mount Packages Ventilate the Spray BoothGeneral Information Prepare the Operator Prepare the SiteSupplied Components Grounding SetupHose Connections Electrical Housing AccessTrigger Lock Pressure Relief ProcedureFlush Before Using Equipment OperationPrime the Pump Install the Spray TipWet Cup Packages with AA Guns Adjust the AtomizationAdjust the Spray Pattern Packages with Airless GunsNo air too little air correct Amount IG . Spray Pattern ProblemsFollow Pressure Relief Procedure, ShutdownFlush the Pump MaintenancePreventive Maintenance Schedule Tighten Threaded ConnectionsProblem Cause Solution TroubleshootingKey for FIG DataTrak Controls and IndicatorsRun Mode Setup ModeRunaway Setup ModeRun Mode DataTrak OperationDisplay DiagnosticsPrime/Flush Counter/TotalizerSymbol Code Code Name Diagnosis Cause Diagnostic CodesReplace Fuse Replace DataTrak Battery or FuseReplace Battery Parts G40 Gun Shown Description Qty G28xxx ModelsW30CBS G30xxx ModelsDescription Qty G48Wxx ModelsNo. Part No. Description Qty KitsWall Mount Kit 24A578 Heated Cart Mount KitRef. Part Description Qty Pump and Gun Control Panel KitKit 24A581 Kit 24A583 Pump Only Control Panel KitKit 24C580 DataTrak KitsPtfe Suction Hose Kits Kit 24A576 with Runaway ProtectionTechnical Data Wall Bracket Mounting DimensionsGraco Information Graco Standard Warranty