Maintenance

If Packing, P/N 20507-00 and Packing Disks,

P/N 20508-00 are removed from Needle and Pack- ing Housing, GlasCraft recommends that these parts always be replaced with NEW packings and packing disks.

1.Ensure spring is seated on needle shoulder.

2.Insert needle into the packing housing .

3.Lubricate a teflon packing disk with red lube and slide into housing.

4.Lubricate the retainer with red lube and slide it into the housing with the flat side entering the housing first. (Concave side entering the housing last).

5.Lubricate the remaining (4) teflon disc and slide them into the housing.

21222-00

20507-00 (Retainer)

6.a. Lubricate the tip of the packing nut, screw it into the housing and hand tighten until it stops.

b.use a 3/8in. wrench on packing nut and a 9/16in. wrench on the packing housing and tighten 1/16 to 1/4 turn.

c.back off then tighten a little more.

d.back off then tighten a little more.

e.back off then snug tight until you hear a “POP”.

Needle Test

1.Put the tip of the needle on a hard surface and press down on the assembly to compress the spring. Release the assembly and the needle should return to it’s origi- nal position.

2.Turn the assembly over and place the back end of the needle on a hard surface and press down until it stops.

Lift up on the spring and lock inside the housing to ensure that the seal has extruded through the hole and surrounds the needle as shown.

GC-1388F

17

Image 17
Contents Indy-X Chop Contents Fire and Explosion Hazard Skin Injection Hazard Methyl Ethyl Ketone Peroxide Mekp Important Safety InformationPolyester Resins and Gel-Coats Spraying and Lamination OperationsGrounding Hose Attachment Set-UpStandard Equipment PartsPart Description Part Description NumberIndy X Chop Dispense Gun Assembly DrawingsAssembly Drawings Assembly Drawings Assembly Drawings Part Description Qty Number Indy X Chop Parts List Description QtyDaily Maintenance Pressure Relief ProcedureParts Replacement Procedure MaintenanceNeedle & Pin Removal Procedures Needle Test Needle & Pin Reassemble Procedure Trigger & Needle Guard Readjustment Procedure Packing Nut Adjustment Procedure Width Output lbs OptionsImpingement Dispense Tips Part Orifice Min Max Part Orifice Number Part OrificeCategory Data Technical DataGraco Ohio Information Graco Ohio Standard Warranty