Graco Inc Indy-X Chop, GC-1388G important safety instructions Needle & Pin Reassemble Procedure

Page 18

Maintenance

Needle & Pin Reassemble Procedure

1.Reassemble the needle assemblies to the gun body. Lubricate the o-rings & use teflon tape on the threads.

2.Make sure the gun pins are lubricated and slide them into the gun block and can be

seen between the gun block and the back side of the trigger and they both are exposed at the back of the gun block near the catalyst and resin needles.

3.Lock-tite both of the set screws, then assemble them to the needle guard using a 5/64in. hex key and make sure they are flush. Fine adjustment will be done after reassembly.

4.Slide the needle guard over the catalyst and resin needles.

5.Attach the collet nuts to exposed needles and hand tighten. Before tightening with a wrench place the needle guard 1/16in. (1.66mm) gap between the gun block and needle guard and tighten using a 3/8in. wrench while holding in place with your hand. Be sure to tighten

1

OK

2 4

 

3

Flush

5

18

GC-1388F

Image 18
Contents Indy-X Chop Contents Fire and Explosion Hazard Skin Injection Hazard Polyester Resins and Gel-Coats Important Safety InformationMethyl Ethyl Ketone Peroxide Mekp Spraying and Lamination OperationsGrounding Set-Up Hose AttachmentPart Description PartsStandard Equipment Part Description NumberAssembly Drawings Indy X Chop Dispense GunAssembly Drawings Assembly Drawings Assembly Drawings Indy X Chop Parts List Description Qty Part Description Qty NumberPressure Relief Procedure Daily Maintenance Maintenance Parts Replacement ProcedureNeedle & Pin Removal Procedures Needle Test Needle & Pin Reassemble Procedure Trigger & Needle Guard Readjustment Procedure Packing Nut Adjustment Procedure Options Impingement Dispense Tips Part Orifice Min MaxWidth Output lbs Part Orifice Part Orifice NumberTechnical Data Category DataGraco Ohio Standard Warranty Graco Ohio Information