Viscosity
Viscosity is the technical term used to indicate the liquidity (thickness or thinness) of the material to be sprayed. Viscosity is measured in the number of seconds required for the material to pass through a Viscosimeter. This Sprayer can spray materials with a viscosity ranging from 10, to a maximum of 60. Material with a higher viscosity can be used only with
PAINT OR MATERIAL | VISCOSITY | THINNING | |
REQUIREMENTS | |||
|
| ||
Filler | 10 to 20 | No thinning | |
|
|
| |
Wood Stain | 15 to 25 | No thinning | |
|
|
| |
20 to 35 | See manufacturer | ||
guidelines | |||
|
| ||
Oil Base Paint | 35 to 40 | See manufacturer | |
guidelines | |||
|
| ||
|
|
| |
40 and higher | See manufacturer | ||
Finishing Products | guidelines | ||
| |||
|
|
|
To test the viscosity of a material:
1.Place your finger over a Viscosimeter (not supplied) output hole.
2.Fill the Viscosimeter to the top with the material to be sprayed.
3.While holding the Viscosimeter over the material source can, let go of the output hole and count the number of seconds it takes for it to empty completely. The number of seconds is the viscosity rating.
Spraying Techniques
1.While spraying, move the Air Spray Gun in parallel strokes to the object being painted.
2.Keep the distance from the Air Spray Gun to the object being painted to 4 to 12 inches. This may be slightly different depending on the flow adjustment and the material being sprayed.
3.Release the Trigger (4) at the end of each forward movement; Pull the Trigger again on the return movement.
4.When using a vertical pattern, move the Spray Gun in a horizontal motion; With a horizontal pattern, move the Spray Gun in a vertical motion. The round pattern requires a greater distance from the object being painted.
SKU 43430 | Page 6 | REV 08/02 |