Grizzly H6331 instruction manual Troubleshooting, Symptom Possible Cause Solution

Page 16

Troubleshooting

Symptom

Possible Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

 

Fluttering or spitting

1. Dry or worn fluid tip seat per-

1.

Tighten fluid tip or replace

spray.

 

mits air to seep into fluid pas-

 

seat with new one.

 

 

 

 

 

 

 

 

 

 

sage.

 

 

 

 

 

 

 

 

 

 

 

2.

Material level too low.

2.

Add material.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Fluid tip or filter obstructed.

3.

Clean

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Dry needle packing.

4.

Lubricate needle.

 

 

 

 

 

 

 

 

 

 

 

 

Uneven top or bot-

1. Atomizing cap holes are

1.

Clear holes.

tom pattern.

 

obstructed.

 

 

 

 

 

 

 

 

 

 

 

2.

Build-up material on top or

2.

Clean.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bottom of fluid tip.

 

 

 

 

 

 

 

 

 

 

 

3.

Build-up material on atomizing

3.

Clean.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cap is on needle seat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Right or left arc

1. Left or right side horn holes

1.

Clear holes.

pattern.

 

are plugged.

 

 

 

 

 

 

 

 

 

 

 

2.

Build-up on left or right side of

2.

Clean.

 

 

 

 

 

 

 

 

 

 

fluid tip.

 

 

 

 

 

 

 

 

 

 

 

3.

Build-up of material inside

3. Clean.

 

 

 

 

 

 

 

 

 

 

atomizing cap.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heavy deposit of

1. The material flow exceeds the

1.

Reduce fluid flow.

material in center.

 

atomizing cap capacity.

 

 

 

 

 

 

 

 

 

 

 

2.

Inlet air pressure is too low.

2.

Increase inlet air pressure.

 

 

 

 

 

 

 

 

 

3.

Material is too thick.

3.

Thin material.

 

 

 

 

 

 

 

 

 

 

 

 

Narrow center pat-

1. Volume control turned in too

1.

Increase volume.

tern.

 

far.

 

 

 

 

 

 

 

 

 

 

 

2.

Inlet air pressure too high.

2.

Reduce inlet air pressure.

 

 

 

 

 

 

 

 

 

3.

Fluid pressure is too low.

3.

Increase fluid pressure.

 

 

 

 

 

 

 

 

 

4.

Material is too thin.

4.

Adjust material.

 

 

 

 

 

 

 

 

 

 

 

 

No spray output.

1. No pressure at gun.

1.

Check air supply.

 

 

 

 

 

 

 

 

 

2.

Fluid passages dirty.

2.

Clean gun, remove any

 

 

 

 

 

 

 

 

 

 

 

 

obstructions.

 

 

 

 

 

 

 

 

 

3.

Fluid control closed.

3.

Open.

 

 

 

 

 

 

 

 

 

4.

Out of paint.

4.

Refill.

 

 

 

 

 

 

 

 

 

5.

Material too thick.

5.

Thin to manufacturer's rec-

 

 

 

 

 

 

 

 

 

 

 

 

ommendations.

 

 

 

 

 

 

 

 

 

 

 

 

 

-16-

Model H6331 HVHP Spray Gun Set

Image 16
Contents Hvhp 2-Pc spray gun SeT Page Table of Contents Safety Safety Instructions for Pneumatic ToolsBefore Operating This Equipment Mation about proper operation of the equipmentMaintain Tools with Care Always USE Safety GlassesNever Leave Unattended Tool Connected to AIR Respiratory Protection Additional Safety Instructions for Hvhp Spray GunsOperating PRESSURE. do Foreword Contact Info IntroductionMachine Data InventoryAssembly SET UPModel H6331 Inventory Figure Controls Reservoir Quick Release LockSpraying OperationsTo use your spray gun Spray technique Atomizing Cap & Fan Adjustments Fan adjustment Model H6331 Hvhp Spray Gun SetAccessories G6261-Campbell Hausfeld Water FilterH7274-Campbell Hausfeld Pressure Regulator H3174-Air Blow Gun with 2 TipsCleaning MaintenanceTo clean your spray gun Lubrication Lubrication pointsTroubleshooting Symptom Possible Cause SolutionSymptom Possible Cause Solution Large Gun Parts List H6331 Parts Breakdown H6331 Large GunSmall Gun Small Gun Parts List H6331Description