SAFETY

Grounding Instructions

TO PREVENT ELECTRIC SHOCK AND DEATH FROM INCORRECT GROUNDING WIRE CONNECTION READ AND FOLLOW THESE INSTRUCTIONS:

110-120 V~ Grounded Tools: Tools with Three Prong Plugs

SETUP

OPERATION

1.In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

2.Do not modify the plug provided – if it will not fit the outlet, have the proper outlet installed by a qualified electrician.

3.Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor.

If repair or replacement of the electric cord or plug is necessary, do not connect the equipment- grounding conductor to a live terminal.

4.Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the tool is properly grounded.

5.Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the tool’s plug.

6. Repair or replace damaged or worn cord immediately.

Grounding

Pin

125 V~ 3-Prong Plug and Outlet (for up to 125 V~ and up to 15 A)

7.This tool is intended for use on a circuit that has an outlet that looks like the one illustrated above in 125 V~ 3-Prong Plug and Outlet. The tool has a grounding plug

that looks like the plug illustrated above in 125 V~ 3-Prong Plug and Outlet.

8.The outlet must be properly installed and grounded in accordance with all codes and ordinances.

9.Do not use an adapter to connect this tool to a different outlet.

Drill Press Safety Warnings

MAINTENANCE

For Your Own Safety Read Instruction

Manual Before Operating Drill Press

1.Wear eye protection.

2.Do not wear gloves, necktie, or loose clothing.

3.Clamp workpiece or brace against column to prevent rotation.

4.Use recommended speed for drill accessory and workpiece material.

5.The included chuck key is specially designed to be self-ejecting, reducing the risk of ejecting at high speed. Only use the included chuck key or an identical replacement key.

6.DO NOT OPERATE WITH ANY GUARD DISABLED, DAMAGED, OR REMOVED. Moving guards must move freely and close instantly.

7.The use of accessories or attachments not recommended by the manufacturer may result in a risk of injury to persons.

8.When servicing use only identical replacement parts.

9.Do not depress the spindle lock when starting or during operation.

10.Only use safety equipment that has been approved by an appropriate standards agency. Unapproved safety equipment may not provide adequate protection. Eye protection must be ANSI-approved and breathing protection must be NIOSH-approved for the specific hazards in the work area.

Page 4

For technical questions, please call 1-800-444-3353.

Item 38142

Image 4
Contents Page Table of Contents General Tool Safety WarningsSafety Setup Operation Maintenance 110-120 V~ Grounded Tools Tools with Three Prong Plugs Drill Press Safety WarningsGrounding Instructions Vibration Safety Assembly SpecificationsSetup Before Use Column Assembly to BaseInstalling the Chuck Table and Support Arm to ColumnHead to Column Pulley Cover KnobInstalling the Drive Belts FunctionsTool Set Up Table AdjustmentSetting a Drilling Depth Operating InstructionsBit Installation Changing Drill SpeedWorkpiece and Work Area Set Up General Operating InstructionsMaintenance and Servicing Cleaning, Maintenance, and LubricationBelt Inspection and Tensioning Troubleshooting Problem Possible Causes Likely SolutionsPulley and Spindle Parts List and Diagram Parts Lists and DiagramsParts List and Diagram a Head Parts List and Diagram B Base and Table Limited 90 Day Warranty