Operating instructions COOL, DRY, HEAT operation

Recommended operation mode:

1

Please use cooling mode in summer and heating mode in winter.

Please use DRY mode in spring or autumn humid climate.

2

R

5

AM

1

 

SETEMP

 

 

AUTO

 

 

 

WOL

 

 

 

 

 

 

 

3

TIMER

CLOCK

 

SWING

 

 

TIME

SLEEP

TEMP

 

SET

 

 

FAN

MODE

 

 

SPEED

 

 

3

4

2

 

 

 

 

4

Unit start

Pressthe"ON/OFF"keytoturnontheunit. TheLCDontheremotecontrollerdisplaystheprev- iousoperatingconditions(excludingprevioustimer, sleep and louver conditions). Theremotecontrolleroperationindicatorturnson.

Select operation mode

Pressthe"MODE"keytoaltertheworkingmode. Eachpressingwillchangetheoperationmodeinthe following sequence:

AUTO COOL DRY FAN HEAT

Theairconditionerwilloperatewiththedisplayed running mode. Selectyourdesiredoperationmodeandgetthedisplay

stop at the corresponding indication.

Select a desired temperature

Press the TEMP setting keys.

Every time pressing the " " key, the temperature setting will increase by 1oC.

Every time pressing the " " key, the temperature setting will decrease by 1oC.

Set a suitable temperature value.

Fan speed selection

Run in COOL mode when

 

room temp. is higher than

 

temp. setting

Ultra-low air supply

Temp.setting + 2oC

Temp. setting

Run in mild DRY mode when the room temp. reaches temp.

PresstheFAN"SPEED"keytochangethefanspeed. Eachpresswillchangethefanspeedinthefollowing

sequence:

 

 

 

 

 

LOW MID

HIGH

 

 

AUTO

 

 

 

L

 

 

L M

 

L M H

 

 

 

 

 

 

 

 

L M H

AUTO

setting +2oC

The air conditioner will run at the fan speed displayed

on the LCD.

In HEAT operation, after unit is turned on, the air conditioner will send out hot air after a short while in order to prevent cold draft.

In DRY operation, when the room temperature decreases to 2oC above temperature setting, the air conditioner will run at low fan speed regardless of the fan speed setting.

5Unit stop

Press "ON/OFF" key to turn off the unit.

Hints:

The remote controller could remember the setting conditions in each operation mode. Upon next time turning on the unit, you need only to press the "ON/OFF" key and the air conditioner will automatically operate with the previous settings. (Except for the timer, sleep and louver conditions).

9

Image 10
Contents AE092FCAHA AE182FCAHA Page Page AE092FCAHA AE182FCAHA Part description Remote controllerClock Set Important Points of Safety Smell etc. occurs, stop running Important Points of Safety Operating instructions Recommended operation mode Operating instructions COOL, DRY, Heat operationTimer ON/OFF function Cancel Timer modeTimer ON-OFF operation Operation Mode Sleep functionTroubleshooting Following cases are not troublesSystem couldnt start Is power on/off switched on? Poor cooling or heating When fault occursPoor cooling Information about application Installation precautions Installing tools Electrical requirements Installation procedurePipe expansion dimensions as follows Pipe cutting and expandingInstallation procedure Choosing the installation location Installation of indoor unit Figure showing installation dimensions unitmmAir supply duct New concrete slab Mount the back cover of the remote controller Installation of remote controllerRemove the back cover of the remote controller Installing the remote controllerRequirements Drain pipeInsulation treatment Supplementary refrigerant Refrigerant pipingAllowable pipe length and drop Pipe material and size RequirementOpen all valves Vacuum pumpingGas leakage detection CElectric wiring Ring terminal connection method Clamping method of the connection wireWire connection for built-in indoor unit Straight terminal connection methodIndoor unit number setting Field settingField setting the unit number Matrix of the dial switch and indoor unit numberList of troubles Installation check and trial operation Wrap with the protective plastic tape

AE092FCAHA, AE182FCAHA specifications

MRV Communications has established itself as a leader in the field of networking solutions, and among its impressive product lineup, the AE182FCAHA and AE092FCAHA stand out as robust fiber optic devices designed to meet the demands of modern network architectures. These devices are particularly tailored for enterprise and service provider environments where high-speed data transmission and reliability are paramount.

The AE182FCAHA is engineered to handle complex networking needs with a combination of high throughput and advanced routing capabilities. It supports multiple protocols, which enables seamless integration into existing infrastructures. This device is capable of delivering up to 10 Gbps of throughput, ensuring that even the most data-intensive applications run smoothly. With its built-in redundancy features, the AE182FCAHA also assures minimal downtime, a critical aspect for mission-critical operations.

Similarly, the AE092FCAHA offers a compelling solution for medium to large-scale networks, focusing on simplified management and high-performance. This device is designed to facilitate bandwidth-intensive applications such as video streaming and large database transactions, with a capacity that supports up to 1 Gbps. It employs sophisticated Quality of Service (QoS) features that prioritize latency-sensitive traffic, making it ideal for real-time communication platforms.

A standout characteristic of both devices is their use of advanced optical technologies. Equipped with DWDM (Dense Wavelength Division Multiplexing), they can transmit multiple signals over a single fiber strand, vastly improving bandwidth efficiency and reducing operational costs. The use of fiber optics also enhances signal integrity over long distances, making these devices suitable for enterprises with expansive geographic footprints.

In terms of management and usability, both the AE182FCAHA and AE092FCAHA come with user-friendly interfaces that streamline configuration and monitoring tasks. Their compatibility with SNMP (Simple Network Management Protocol) allows network administrators to easily integrate them into larger management systems, ensuring proactive monitoring and quick troubleshooting.

Overall, MRV Communications' AE182FCAHA and AE092FCAHA are innovative solutions designed to meet the rigorous demands of today's networking environments, combining high performance, advanced features, and ease of management. Organizations looking to enhance their network infrastructure will find these devices to be dependable assets that support both current requirements and future expansion.