MRV Communications AE092FCAHA, AE182FCAHA manual Installation precautions

Page 18

Installation precautions

Before installing, do read this "Safety precautions" carefully to guarantee the proper installation.

The below attentive matters are divided into" ! Warning " and "! Note" two parts. When the wrong installation occur, it is very possible death and severe injury and other serious accidents will

happen. For those items are listed in "

!

Warning"part. But

even the

items listed in " Note"

 

 

 

!

part can also cause serious accidents. Above

all, both the

two parts

are very important contents

related to safety, so they must be obeyed.

After finishing the installation work, do test run to verify everything is normal. After that please explain the using and maintenance methods to the user. Additionally, give this installation manual and operation manual to the user and ask them to keep it properly.

!Warning

The distributing shop, where you bought the air conditioner,

or

the specified shops

shall

do the

installation work. If you do the installation work by yourself, the

improper

installation

will

cause

water leakage, electric shock fire and other accidents.

 

 

 

 

 

 

 

 

The installation work shall be in line with what the

installation

manual

specified. If installation

is not proper, water leakage, electric shock, fire and other accidents will occur.

 

 

Install the air conditioner to a place where can definitely stand its weight. Places not

firm

enough

will cause drop down of unit resulting in body hurt.

 

 

 

 

 

 

 

 

 

The installation work shall be preventive to

typhoon and

earthquake. If

the installation work is

not met with the requirements, overturn of the unit will occur resulting in accidents.

 

 

The wiring work shall be done by a qualified

person

and

referred

to

the " technical

standard of

electric equipment" , "indoor wiring regulation"

and

what

the

manual

specified.

Do

use

special circuit. If the capacity of the circuit is not enough or bad work, electric shock, fire and other accidents will happen.

Using the specified cable to do wiring work and connecting firmly and properly. Fix the connecting part of the terminals to prevent it from the external force.Improper connection and fixing will cause heating and fire etc. accidents.

Wiring shall be kept in correct shape avoiding extrusion. After installation, the electric box cover and the external panel shall not nip the wire. Improper installation will cause heating and fire etc. accidents.

When setting or moving the air conditioner do not let the air and things alike get into the refrigeration system except the specified refrigerant (R22). If air and other things enter, abn- ormal high pressure will occur, which easily cause break and body injuries etc. Accidents.

When installing, do use the accessories or specified parts. If not using the parts specified by our company, water leakage, electric shock, fire and refrigerant leakage will occur.

Do not lead the drainpipe to drain where the sulfur gas may be involved. Otherwise, the poisonous gas will enter into the indoor.

During installation, if refrigerant leakage occurs, do the ventilation work immediately. As soon as the refrigerant gas meets fire, poisonous gas will be produce. If the refrigerant gas enters into room and meet the air blowing heater, heater or stove etc. fire source, the poisonous gas may be produced. After installation, confirm there is no leakage of refrigerant.

Do not install the unit in a place where the combustible gas may be leaked. In any case the combustible gas leaks and accumulated around the unit, fire accident will occur.

Do heat insulation work to the refrigerant gas pipes and liquid pipes to reach the purpose of heat preservation. If the heat insulation measure is not sufficient, water generated by condensing dew will drip leading to wet the floor and indoor articles.

!Note

Do grounding work.Do not connect the grounding wire to gas pipe,tap,lighting rod or telephone line.Improper grounding will cause electric shock.

After electric installation,power on them to do electric leakage test.

1 7

Image 18
Contents AE092FCAHA AE182FCAHA Page Page AE092FCAHA AE182FCAHA Remote controller Part descriptionClock Set Important Points of Safety Smell etc. occurs, stop running Important Points of Safety Operating instructions Recommended operation mode Operating instructions COOL, DRY, Heat operationTimer ON/OFF function Cancel Timer modeTimer ON-OFF operation Operation Mode Sleep functionTroubleshooting Following cases are not troublesSystem couldnt start Is power on/off switched on? When fault occurs Poor cooling or heatingPoor cooling Information about application Installation precautions Installing tools Electrical requirements Installation procedurePipe expansion dimensions as follows Pipe cutting and expandingInstallation procedure Choosing the installation location Installation of indoor unit Figure showing installation dimensions unitmmAir supply duct New concrete slab Mount the back cover of the remote controller Installation of remote controllerRemove the back cover of the remote controller Installing the remote controllerDrain pipe RequirementsInsulation treatment Supplementary refrigerant Refrigerant pipingAllowable pipe length and drop Pipe material and size RequirementVacuum pumping Open all valvesGas leakage detection CElectric wiring Ring terminal connection method Clamping method of the connection wireWire connection for built-in indoor unit Straight terminal connection methodIndoor unit number setting Field settingField setting the unit number Matrix of the dial switch and indoor unit numberList of troubles Installation check and trial operation Wrap with the protective plastic tape

AE092FCAHA, AE182FCAHA specifications

MRV Communications has established itself as a leader in the field of networking solutions, and among its impressive product lineup, the AE182FCAHA and AE092FCAHA stand out as robust fiber optic devices designed to meet the demands of modern network architectures. These devices are particularly tailored for enterprise and service provider environments where high-speed data transmission and reliability are paramount.

The AE182FCAHA is engineered to handle complex networking needs with a combination of high throughput and advanced routing capabilities. It supports multiple protocols, which enables seamless integration into existing infrastructures. This device is capable of delivering up to 10 Gbps of throughput, ensuring that even the most data-intensive applications run smoothly. With its built-in redundancy features, the AE182FCAHA also assures minimal downtime, a critical aspect for mission-critical operations.

Similarly, the AE092FCAHA offers a compelling solution for medium to large-scale networks, focusing on simplified management and high-performance. This device is designed to facilitate bandwidth-intensive applications such as video streaming and large database transactions, with a capacity that supports up to 1 Gbps. It employs sophisticated Quality of Service (QoS) features that prioritize latency-sensitive traffic, making it ideal for real-time communication platforms.

A standout characteristic of both devices is their use of advanced optical technologies. Equipped with DWDM (Dense Wavelength Division Multiplexing), they can transmit multiple signals over a single fiber strand, vastly improving bandwidth efficiency and reducing operational costs. The use of fiber optics also enhances signal integrity over long distances, making these devices suitable for enterprises with expansive geographic footprints.

In terms of management and usability, both the AE182FCAHA and AE092FCAHA come with user-friendly interfaces that streamline configuration and monitoring tasks. Their compatibility with SNMP (Simple Network Management Protocol) allows network administrators to easily integrate them into larger management systems, ensuring proactive monitoring and quick troubleshooting.

Overall, MRV Communications' AE182FCAHA and AE092FCAHA are innovative solutions designed to meet the rigorous demands of today's networking environments, combining high performance, advanced features, and ease of management. Organizations looking to enhance their network infrastructure will find these devices to be dependable assets that support both current requirements and future expansion.