MRV Communications AE092FCAHA, AE182FCAHA manual Installation of indoor unit

Page 22

Installation procedure

Installation of indoor unit

! Warning

•The unit shall be installed at locations enough to support the unit. If not, the air conditioner

may fall down and cause personal injury.

•The unit shall be installed according to the specifications to resist to strong wind and earthquake. Improper installation may cause

dangers of unit falling down etc.

After selecting the unit installation location, proceed the following steps:

1.Drill a hole in the wall and insert the connecting pipe and wire through a PVC wall-through tube purchased locally. The wall hole shall be with a outward down slope of at least 1/100. (See Figure 2)

2.Before drilling check that there is no pipe or reinforcing bar just behind the drilling position. Drilling shall avoid at positions with electric wire or pipe.

3.Mount the unit on a strong and horizontal building roof. If the base is not firm, it will cause noise, vibration or leakage (see Figure 6).

4.Support the unit firmly.

5.Change the form of the connection pipe, connection wire and drain pipe so that they can go through the wall hole easily.

Figure showing installation dimensions: (unit:mm)

223

1100

Fig 2

AE182FCAHA

AE092FCAHA

21

Image 22
Contents AE092FCAHA AE182FCAHA Page Page AE092FCAHA AE182FCAHA Part description Remote controllerClock Set Important Points of Safety Smell etc. occurs, stop running Important Points of Safety Operating instructions Recommended operation mode Operating instructions COOL, DRY, Heat operationTimer ON/OFF function Cancel Timer modeTimer ON-OFF operation Operation Mode Sleep functionTroubleshooting Following cases are not troublesSystem couldnt start Is power on/off switched on? Poor cooling or heating When fault occursPoor cooling Information about application Installation precautions Installing tools Electrical requirements Installation procedurePipe expansion dimensions as follows Pipe cutting and expandingInstallation procedure Choosing the installation location Installation of indoor unit Figure showing installation dimensions unitmmAir supply duct New concrete slab Mount the back cover of the remote controller Installation of remote controllerRemove the back cover of the remote controller Installing the remote controllerRequirements Drain pipeInsulation treatment Supplementary refrigerant Refrigerant pipingAllowable pipe length and drop Pipe material and size RequirementOpen all valves Vacuum pumpingGas leakage detection CElectric wiring Ring terminal connection method Clamping method of the connection wireWire connection for built-in indoor unit Straight terminal connection methodIndoor unit number setting Field settingField setting the unit number Matrix of the dial switch and indoor unit numberList of troubles Installation check and trial operation Wrap with the protective plastic tape

AE092FCAHA, AE182FCAHA specifications

MRV Communications has established itself as a leader in the field of networking solutions, and among its impressive product lineup, the AE182FCAHA and AE092FCAHA stand out as robust fiber optic devices designed to meet the demands of modern network architectures. These devices are particularly tailored for enterprise and service provider environments where high-speed data transmission and reliability are paramount.

The AE182FCAHA is engineered to handle complex networking needs with a combination of high throughput and advanced routing capabilities. It supports multiple protocols, which enables seamless integration into existing infrastructures. This device is capable of delivering up to 10 Gbps of throughput, ensuring that even the most data-intensive applications run smoothly. With its built-in redundancy features, the AE182FCAHA also assures minimal downtime, a critical aspect for mission-critical operations.

Similarly, the AE092FCAHA offers a compelling solution for medium to large-scale networks, focusing on simplified management and high-performance. This device is designed to facilitate bandwidth-intensive applications such as video streaming and large database transactions, with a capacity that supports up to 1 Gbps. It employs sophisticated Quality of Service (QoS) features that prioritize latency-sensitive traffic, making it ideal for real-time communication platforms.

A standout characteristic of both devices is their use of advanced optical technologies. Equipped with DWDM (Dense Wavelength Division Multiplexing), they can transmit multiple signals over a single fiber strand, vastly improving bandwidth efficiency and reducing operational costs. The use of fiber optics also enhances signal integrity over long distances, making these devices suitable for enterprises with expansive geographic footprints.

In terms of management and usability, both the AE182FCAHA and AE092FCAHA come with user-friendly interfaces that streamline configuration and monitoring tasks. Their compatibility with SNMP (Simple Network Management Protocol) allows network administrators to easily integrate them into larger management systems, ensuring proactive monitoring and quick troubleshooting.

Overall, MRV Communications' AE182FCAHA and AE092FCAHA are innovative solutions designed to meet the rigorous demands of today's networking environments, combining high performance, advanced features, and ease of management. Organizations looking to enhance their network infrastructure will find these devices to be dependable assets that support both current requirements and future expansion.