Carrier 30RAP010-060 installation instructions 38RAP Unit Voltage

Page 22

Table 11 — 30RAP Electrical Data — Hydronic Package with Standard Low-Sound AeroAcoustic™ Fan

38RAP UNIT

VOLTAGE

 

 

PUMP SIZE 1 hp

 

 

 

PUMP SIZE 1.5 hp

 

 

 

PUMP SIZE 2 hp

 

 

PUMP OPTIONS "1" OR "8"

 

PUMP OPTIONS "2" OR "9"

 

PUMP OPTIONS "3" OR "B"

SIZE

V-Hz (3 Ph)

 

 

 

 

 

MCA

 

MOCP

ICF

REC FUSE

MCA

 

MOCP

ICF

REC FUSE

MCA

 

MOCP

ICF

REC FUSE

 

208/230-60

69.4

 

110

254.3

90

70.6

 

110

255.4

90

71.7

 

110

256.6

90

010

380-60

35.5

 

50

253.0

45

36.2

 

50

151.6

45

60.5

 

60

152.2

45

460-60

27.8

 

45

252.6

35

28.4

 

45

130.1

35

28.9

 

45

130.6

35

 

 

 

 

 

575-60

22.1

 

35

252.3

30

22.6

 

35

104.2

30

22.9

 

35

104.5

30

 

208/230-60

79.0

 

125

349.3

100

80.2

 

125

350.4

100

81.4

 

125

351.6

100

015

380-60

48.4

 

80

348.0

60

49.1

 

80

202.6

60

83.7

 

80

203.2

60

460-60

38.2

 

60

347.6

45

38.7

 

60

184.1

50

39.2

 

60

184.6

50

 

 

 

 

 

575-60

33.3

 

50

347.3

40

33.8

 

50

136.2

40

34.2

 

50

136.5

45

 

208/230-60

90.4

 

110

273.7

100

91.6

 

110

274.8

100

92.8

 

125

276.0

110

018

380-60

53.0

 

70

272.4

60

53.8

 

70

169.7

60

73.6

 

70

170.3

60

460-60

45.0

 

60

272.0

50

45.6

 

60

138.7

50

46.1

 

60

139.2

60

 

 

 

 

 

575-60

36.2

 

45

271.7

40

36.7

 

50

100.0

45

37.0

 

50

100.3

45

 

208/230-60

95.8

 

125

290.1

110

97.0

 

125

291.2

110

98.2

 

125

292.4

110

020

380-60

63.1

 

80

288.8

70

63.9

 

80

179.2

70

88.2

 

80

179.8

80

460-60

47.7

 

60

288.4

60

48.3

 

60

150.9

60

48.8

 

60

151.4

60

 

 

 

 

 

575-60

38.3

 

50

288.1

45

38.8

 

50

100.9

45

39.2

 

50

101.3

45

 

208/230-60

130.7

 

175

366.6

150

131.9

 

175

367.7

150

133.0

 

175

368.9

150

025

380-60

70.3

 

90

365.3

80

71.0

 

90

176.4

80

98.5

 

90

177.0

80

460-60

59.4

 

80

364.9

70

60.0

 

80

181.1

70

60.5

 

80

181.6

70

 

 

 

 

 

575-60

50.9

 

70

364.6

60

51.4

 

70

135.5

60

51.7

 

70

135.8

60

 

208/230-60

140.8

 

175

411.1

175

142.0

 

175

412.2

175

143.2

 

175

413.4

175

030

380-60

86.3

 

110

409.8

100

87.0

 

110

240.5

100

121.6

 

110

241.1

100

460-60

68.0

 

90

409.4

80

68.5

 

90

213.9

80

69.0

 

90

214.4

80

 

 

 

 

 

575-60

59.4

 

80

409.1

70

59.9

 

80

162.3

70

60.3

 

80

162.6

70

 

208/230-60

168.6

 

200

344.9

200

169.8

 

200

346.0

200

171.0

 

200

347.2

200

035

380-60

105.5

 

125

343.6

125

106.2

 

125

209.9

125

130.5

 

125

210.5

125

460-60

84.0

 

100

343.2

90

84.6

 

100

178.5

90

85.1

 

100

179.0

90

 

 

 

 

 

575-60

67.5

 

80

342.9

80

67.9

 

80

122.8

80

68.3

 

80

123.2

80

 

208/230-60

198.0

 

225

380.3

225

199.2

 

225

381.4

225

200.4

 

225

382.6

225

040

380-60

114.4

 

125

379.0

125

115.2

 

125

218.8

125

139.5

 

125

219.4

125

460-60

87.8

 

100

378.6

100

88.4

 

100

182.3

100

88.9

 

100

182.8

100

 

 

 

 

 

575-60

70.1

 

80

378.3

80

70.6

 

80

145.5

80

71.0

 

80

145.9

80

 

208/230-60

232.9

 

250

454.0

250

234.1

 

250

455.1

250

235.2

 

250

456.3

250

045

380-60

121.6

 

125

452.7

125

122.3

 

125

219.2

125

149.8

 

125

219.8

125

460-60

99.5

 

110

452.3

110

100.1

 

110

217.0

110

100.6

 

110

217.5

110

 

 

 

 

 

575-60

82.7

 

100

452.0

90

83.2

 

100

165.3

90

83.5

 

100

165.6

90

 

208/230-60

239.3

 

250

457.2

250

240.5

 

250

458.3

250

241.6

 

250

459.5

250

050

380-60

128.0

 

150

455.9

150

128.7

 

150

222.4

150

156.2

 

150

223.0

150

460-60

108.5

 

125

455.5

125

109.1

 

125

221.5

125

109.6

 

125

222.0

125

 

 

 

 

 

575-60

93.1

 

110

455.2

100

93.6

 

110

170.5

100

93.9

 

110

170.8

100

 

208/230-60

255.4

 

300

506.2

300

256.6

 

300

507.3

300

257.8

 

300

508.5

300

055

380-60

147.9

 

175

504.9

175

148.6

 

175

293.6

175

183.2

 

175

294.2

175

460-60

120.0

 

125

504.5

125

120.5

 

125

258.1

125

121.0

 

125

258.6

125

 

 

 

 

 

575-60

104.0

 

125

504.2

110

104.5

 

125

201.1

125

104.9

 

125

201.4

125

 

208/230-60

264.4

 

300

510.7

300

265.6

 

300

511.8

300

266.8

 

300

513.0

300

060

380-60

162.1

 

175

509.4

175

162.8

 

175

300.7

175

197.4

 

175

301.3

175

460-60

127.6

 

150

509.0

150

128.1

 

150

261.9

150

128.6

 

150

262.4

150

 

 

 

 

 

575-60

111.6

 

125

508.7

125

112.1

 

125

204.9

125

112.5

 

125

205.2

125

LEGEND

ICF — Instantaneous Current Flow

MCA — Minimum Circuit Amps

MOCP — Maximum Overcurrent Protection

NOTES:

1.Units are suitable for use on electrical systems where voltage supplied to the unit ter- minals is not below or above the listed minimum and maximum limits. Maximum allow- able phase imbalance is: voltage, 2%; amps 10%.

2.All units/modules have single point primary power connection. (Each unit/module requires its own power supply.) Main power must be supplied from a field-supplied disconnect.

3.Cooler heater is wired into the control circuit so it is always operable as long as the power supply disconnect is on, even if any safety device is open.

22

Image 22
Contents Installation Instructions Quality Assurance Unit Operating Weights A30-4861Physical Data, 30RAP English Unit 30RAPPhysical Data, 30RAP SI Cooler Fluid and Drain Piping Con- nections Check Compressor Mounting AsA30-4916 Dimensions 30RAP010 and 015 Units A30-4948Dimensions 30RAP018-030 Units A30-4949Dimensions 30RAP035-060 Units Accessory Storage Tank Dimensions 30RAP010,015 Units A30-4879Accessory Storage Tank Dimensions 30RAP018-030 Units A30-4880Accessory Storage Tank Dimensions 30RAP035-060 Units A30-4880 A30-4881Typical Piping Diagram 30RAP Units with Hydronic Package Factor for Setting Tank Pressure A30-4635Water Quality Characteristics Limitations Fill the Chilled Water LoopTypical Set Up for Cleaning Process Head Ft Water as Read on Balancing Valve for 30RAP035-060 Head Ft Water as Read on Balancing Valve for 30RAP010-030Head kPa as Read on Balancing Valve for 30RAP010-030 Head kPa as Read on Balancing Valve for 30RAP035-060Heat Exchanger Pressure Drop 30RAP035-060 English Minimum Fluid Volume In Circulation Heat Exchanger Pressure Drop 30RAP035-060 SIWind Baffle Accessory Quantities Make Electrical ConnectionsMaximum Field Wiring Sizes 30RAP Electrical Data No Hydronic Package38RAP Unit Voltage Pump Size 3 hp Pump Size 5 hp Pump Size 7.5 hp Hz 3 Ph 208/230-60 75.3 110 260.2 80.1 125 265.0 100 86.7 271.6 Fan Electrical Data Standard Low-Sound AeroAcoustic Fans Fan Electrical Data Optional Value Sound FansAccessory Tank Electrical Data Pump Electrical DataCompressor Electrical Data PER Circuit RLA LRAInstall Accessories Check Refrigerant CircuitTypical Main Power and Control Connections Suction Access Port Sizes 018-030 Shown Unit Pressure Drop Curves, 30RAP010-060 Units Without Hydronic Package EnglishAppendix a Unit Pressure Drop Curves, 30RAP010-060 KPa Drop Water Pressure Liters/SecondUnits with Single Pump Hydronic Package English Units with Single Pump Hydronic Package SI Units with Dual Pump Hydronic Package English Units with Dual Pump Hydronic Package SI Appendix a Pressure Drop Curves, Accessory Storage Tanks Accessory Tank Flow Rate L/sPage Copyright 2009 Carrier Corporation
Related manuals
Manual 124 pages 40.33 Kb

30RAP010-060 specifications

The Carrier 30RAP010-060 is a series of rooftop air conditioning units designed for effective climate control in commercial applications. Engineered with advanced technologies, these units are known for their reliability, energy efficiency, and ease of installation, making them a suitable choice for a range of settings including offices, retail spaces, and industrial facilities.

One of the standout features of the 30RAP series is its robust construction. Designed to withstand various environmental conditions, these units come equipped with a weather-resistant cabinet and a corrosion-resistant finish. This durability ensures long-term performance and reduced maintenance costs.

Energy efficiency is a significant characteristic of the Carrier 30RAP series. These units utilize advanced technologies such as a high-efficiency compressor and variable speed fans. The inclusion of economizers also contributes to energy savings by allowing the system to take advantage of outdoor air when the conditions are favorable. With high SEER (Seasonal Energy Efficiency Ratio) ratings, the 30RAP units help businesses reduce operating costs while minimizing their environmental footprint.

The 30RAP series is equipped with smart control systems that provide enhanced operational efficiency and comfort. With features such as programmable thermostats and remote access capabilities, building managers can easily monitor and adjust the system to maintain optimal indoor climate conditions. Additionally, the units are compatible with building automation systems, allowing for seamless integration into a larger HVAC network.

The installation process of the Carrier 30RAP010-060 is streamlined thanks to a compact design and lightweight construction, which simplifies the transportation and placement on rooftops. Moreover, the unit's modular components facilitate easy access for maintenance and repairs, minimizing downtime and improving overall reliability.

In summary, the Carrier 30RAP010-060 series stands out for its combination of durability, energy efficiency, and advanced control technologies. It is an ideal solution for businesses seeking reliable climate control systems that balance performance with cost-effectiveness. Whether for new installations or replacements, these rooftop units provide the necessary flexibility and efficiency needed in today’s commercial environments. With strong backing from Carrier, a leader in HVAC technology, the 30RAP series ensures lasting comfort and operational efficiency.