MOUNTING UNIT — When unit is in proper location, use of mounting holes in base rails is recommended for securing unit to supporting structure, or for mounting unit on vibration isolators if required. See Fig. 4. Fasteners for mounting unit are field supplied. Be sure unit is level to within 1/8 in. per foot for proper oil return to compressor.

Step 2 — Check Compressor Mounting — As

shipped, units with single compressors are held down with 4 bolts through rubber grommets. All units with tandem com- presors are held down with 6 bolts per pair through grommets. After unit is installed, verify mounting bolt torque 7 to10 ft-lb.

Step 3 — Cooler Fluid and Drain Piping Con- nections

ALL UNITS — These chillers are supplied with factory- installed strainer (including blow-down valve) in the entering fluid piping and flow switch in the leaving fluid piping. Flow switch wiring is factory installed. .

CAUTION

Do not circulate water through unit without strainer in place. Failure to use the strainer represents abuse and may impair or otherwise negatively affect the Carrier product warranty.

Piping connections are located on the front of the chiller when facing the control panel for sizes 010 to 030 and at the

a30-4916

end opposite the control panel for sizes 035 to 060. See Fig. 5-10, depending on model.

All sizes have victaulic connections as shown in the physi- cal data tables. Provide a means of venting air from the high point of the field-installed piping as required. Install field-sup- plied drains in both the entering and leaving fluid connections.

After field piping is complete, freeze-up protection is rec- ommended using inhibited ethylene glycol or other suitable in- hibited antifreeze solution and electric heat tapes in areas where piping is exposed to low ambient temperatures (34 F [1 °C] or below). Heat tapes should possess a rating for area ambients and be covered with a suitable thickness of closed- cell insulation. Route power for heating tapes from a separately fused disconnect. Identify disconnect as heat tape power source with a warning that power must not be turned off except when unit is being serviced.

The water connections are copper victaulic. Any connecting pipe to the 30RAP pump package must be of a material that will not cause any galvanic corrosion. For this reason, galva- nized steel pipe or other dissimilar metals must not be used un- less joined by a dielectric coupling.

Installation of water systems should follow sound engineer- ing practice as well as applicable local and industry standards. Improperly designed or installed systems may cause unsatis- factory operation and/or system failure. Consult a water treat- ment specialist or appropriate literature for information regard- ing filtration, water treatment, and control devices.

Fig. 4 — Unit Rigging Label Detail

6

Image 6
Contents Installation Instructions Quality Assurance Unit Operating Weights A30-4861Physical Data, 30RAP English Unit 30RAPPhysical Data, 30RAP SI Check Compressor Mounting As Cooler Fluid and Drain Piping Con- nectionsA30-4916 Dimensions 30RAP010 and 015 Units A30-4948Dimensions 30RAP018-030 Units A30-4949Dimensions 30RAP035-060 Units Accessory Storage Tank Dimensions 30RAP010,015 Units A30-4879Accessory Storage Tank Dimensions 30RAP018-030 Units A30-4880Accessory Storage Tank Dimensions 30RAP035-060 Units A30-4880 A30-4881Typical Piping Diagram 30RAP Units with Hydronic Package Factor for Setting Tank Pressure A30-4635Water Quality Characteristics Limitations Fill the Chilled Water LoopTypical Set Up for Cleaning Process Head Ft Water as Read on Balancing Valve for 30RAP035-060 Head Ft Water as Read on Balancing Valve for 30RAP010-030Head kPa as Read on Balancing Valve for 30RAP010-030 Head kPa as Read on Balancing Valve for 30RAP035-060Heat Exchanger Pressure Drop 30RAP035-060 English Minimum Fluid Volume In Circulation Heat Exchanger Pressure Drop 30RAP035-060 SIWind Baffle Accessory Quantities Make Electrical ConnectionsMaximum Field Wiring Sizes 30RAP Electrical Data No Hydronic Package38RAP Unit Voltage Pump Size 3 hp Pump Size 5 hp Pump Size 7.5 hp Hz 3 Ph 208/230-60 75.3 110 260.2 80.1 125 265.0 100 86.7 271.6 Fan Electrical Data Standard Low-Sound AeroAcoustic Fans Fan Electrical Data Optional Value Sound FansAccessory Tank Electrical Data Pump Electrical DataCompressor Electrical Data PER Circuit RLA LRAInstall Accessories Check Refrigerant CircuitTypical Main Power and Control Connections Suction Access Port Sizes 018-030 Shown Unit Pressure Drop Curves, 30RAP010-060 Units Without Hydronic Package EnglishAppendix a Unit Pressure Drop Curves, 30RAP010-060 KPa Drop Water Pressure Liters/SecondUnits with Single Pump Hydronic Package English Units with Single Pump Hydronic Package SI Units with Dual Pump Hydronic Package English Units with Dual Pump Hydronic Package SI Appendix a Pressure Drop Curves, Accessory Storage Tanks Accessory Tank Flow Rate L/sPage Copyright 2009 Carrier Corporation
Related manuals
Manual 124 pages 40.33 Kb

30RAP010-060 specifications

The Carrier 30RAP010-060 is a series of rooftop air conditioning units designed for effective climate control in commercial applications. Engineered with advanced technologies, these units are known for their reliability, energy efficiency, and ease of installation, making them a suitable choice for a range of settings including offices, retail spaces, and industrial facilities.

One of the standout features of the 30RAP series is its robust construction. Designed to withstand various environmental conditions, these units come equipped with a weather-resistant cabinet and a corrosion-resistant finish. This durability ensures long-term performance and reduced maintenance costs.

Energy efficiency is a significant characteristic of the Carrier 30RAP series. These units utilize advanced technologies such as a high-efficiency compressor and variable speed fans. The inclusion of economizers also contributes to energy savings by allowing the system to take advantage of outdoor air when the conditions are favorable. With high SEER (Seasonal Energy Efficiency Ratio) ratings, the 30RAP units help businesses reduce operating costs while minimizing their environmental footprint.

The 30RAP series is equipped with smart control systems that provide enhanced operational efficiency and comfort. With features such as programmable thermostats and remote access capabilities, building managers can easily monitor and adjust the system to maintain optimal indoor climate conditions. Additionally, the units are compatible with building automation systems, allowing for seamless integration into a larger HVAC network.

The installation process of the Carrier 30RAP010-060 is streamlined thanks to a compact design and lightweight construction, which simplifies the transportation and placement on rooftops. Moreover, the unit's modular components facilitate easy access for maintenance and repairs, minimizing downtime and improving overall reliability.

In summary, the Carrier 30RAP010-060 series stands out for its combination of durability, energy efficiency, and advanced control technologies. It is an ideal solution for businesses seeking reliable climate control systems that balance performance with cost-effectiveness. Whether for new installations or replacements, these rooftop units provide the necessary flexibility and efficiency needed in today’s commercial environments. With strong backing from Carrier, a leader in HVAC technology, the 30RAP series ensures lasting comfort and operational efficiency.