RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*
(120 or 240 VOLT)
NAMEPLATE |
|
|
|
| EXTENSION CORD LENGTH |
| ||||||||
AMPERES |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
(at full load) | 25 Feet |
| 50 Feet |
| 75 Feet |
| 100 Feet | 150 Feet | ||||||
0 – 2.0 | 18 |
| 18 |
| 18 |
| 18 | 16 | ||||||
2.1 | – 3.4 | 18 |
| 18 |
| 18 |
| 16 | 14 | |||||
3.5 | – 5.0 | 18 |
| 18 |
| 16 |
| 14 | 12 | |||||
5.1 | – 7.0 | 18 |
| 16 |
| 14 |
| 12 | 12 | |||||
7.1 – 12.0 | 18 |
| 14 |
| 12 |
| 10 | - | ||||||
12.1 | – 16.0 | 14 |
| 12 |
| 10 |
| - |
| - | ||||
16.1 | – 20.0 | 12 |
| 10 |
| - |
| - |
| - | ||||
TABLE A | * Based on limiting the line voltage drop to five volts at 150% of the rated amperes. | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|