areas.
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*
NAMEPLATE |
|
|
|
|
|
|
| |
AMPERES |
|
| EXTENSION CORD LENGTH |
| ||||
(At Full Load) |
|
|
|
|
|
|
| |
|
| 25 Feet |
| 50 Feet | 75 Feet | 100 Feet |
| 150 Feet |
|
|
|
|
|
|
|
| |
0 - 2.0 | 18 |
| 18 | 18 | 18 |
| 16 | |
|
|
|
|
|
|
|
|
|
2.1 | - 3.4 | 18 |
| 18 | 18 | 16 |
| 14 |
|
|
|
|
|
|
|
|
|
3.5 | - 5.0 | 18 |
| 18 | 16 | 14 |
| 12 |
|
|
|
|
|
|
|
|
|
5.1 | - 7.0 | 18 |
| 16 | 14 | 12 |
| 12 |
|
|
|
|
|
|
|
| |
7.1 - 12.0 | 18 |
| 14 | 12 | 10 |
| - | |
|
|
|
|
|
|
|
|
|
12.1 | - 16.0 | 14 |
| 12 | 10 | - |
| - |
|
|
|
|
|
|
|
|
|
16.1 | - 20.0 | 12 |
| 10 | - | - |
| - |
|
|
|
|
|
|
|
|
|
FIGURE C |
| * Based on limiting the line voltage drop to five volts at |
| |||||
|
| 150% of the rated amperes. |
| |||||
|
|
|
|
|
|
|
|
|
| Symbology | |
|
|
|
|
|
|
|
|
|
|
|
| Double Insulated |
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Canadian Standards Association |
|
|
|
|
|
|
|
|
|
|
|
|
| Underwriters Laboratories, Inc. |
|
|
|
|
|
|
|
|
| V~ | Volts Alternating Current |
| |||
|
| A | Amperes |
| ||
|
|
|
|
|
| |
|
|
|
|
|
|
|
| n0 xxxx/min. | No Load Revolutions per Minute (RPM) |
|
SKU 55167 | For technical questions, please call | Page 10 | |