Fluke 787 user manual Pushbuttons Functions

Page 16

787

Users Manual

2

3

4

5

MIN MAX

RANGE

% STEP COARSE

REL

1

8

HOLD H

FINE

Hz

6

7

ee003f.eps

Figure 5. Pushbuttons

No.

A

B

Pushbutton

b

U

(BLUE)

Table 5. Pushbuttons

Function(s)

Toggles the backlight

Rotary switch in mA A Lposition and test lead plugged into cA jack: Toggles between ac and dc ampere measure

Rotary switch in Oposition: Selects diode test function (D)

Rotary switch in OUTPUT mA Jposition: Cycles through

Slow repeating 0% -100% - 0% ramp (Eon display)

Fast repeating 0% -100% - 0% ramp (Pon display)

Repeating 0% -100% - 0% ramp in 25% steps (Non display)

12

Image 16
Contents 787 Limited Warranty & Limitation of Liability Table of Contents 787 IndexIntroduction Read Safety Information before you use the meterContacting Fluke Safety Information 787ProcessMeter International Symbols Meaning Symbol MeaningHow to Get Started Fluke 787 ProcessMeterGetting Acquainted with the Meter Input/Output JacksSource Current Function Input/Output Jacks Measurement FunctionsSimulate Transmitter Function Rotary Switch Positions for Measurements Functions Pushbutton ActionsRotary Switch Positions for mA Output Default Function Pushbuttons Pushbuttons FunctionsPushbutton CoarseElements of the Display Element Display MeaningDisplay Element MA, DC, mV, AC Or kΩ, kHz Auto 400100030 Measuring a Composite Signal Measuring Electrical ParametersInput Impedance RangesTesting Diodes Displaying Minimum, Maximum, and AverageUsing TouchHold Compensating for Test Lead ResistanceUsing the Current Output Functions Source ModeSourcing Current Simulate Mode Changing the Current SpanSimulating a Transmitter Adjustment MA Output Adjust PushbuttonsProducing a Steady mA Output Manually Stepping the mA Output MA Stepping PushbuttonsMA Step Values Value for each span setting To 20 mA Auto Ramping the mA OutputPower-Up Options Power-Up OptionsPushbutton Default Action TakenBattery Life Using the Holster and Flex-StandMaintenance General MaintenanceUsing the Holster and Flex-Stand Replacing the Battery Replacing the BatteryReplacing a Fuse If the Meter does not Work Replacing a FuseReplacement Parts and Accessories Replacement Parts DescriptionFluke PN or Model no QuantityMP8 Specifications ResolutionDC Volts Measurement Range V dcDC Millivolts Measurement Range mV dc Resolution 400.0 Accuracy % of Reading + CountsAC Volts Measurement AC Current Measurement DC Current MeasurementOhms Measurement Range ResolutionMeasurement Current Frequency Counter Sensitivity Frequency Counter AccuracyInput Range Minimum Sensitivity rms Sinewave 5 Hz to 5 kHz General Specifications Source modeSimulate Mode Diode Test and Continuity TestCertifications CSA, UL, TÜV Index Knob positions, 9 Pushbuttons Loop supply, external Index 787