Fluke 787 user manual Element, Display Meaning

Page 19

ProcessMeter

Getting Acquainted with the Meter

No.

A

B

C

D

E

F

G

H

I

Element

Percentage display

OUTPUT

D

S

Q

B

Numerals

H

MINMAXAVGR

Table 6. Display

Meaning

Shows the mA measured value or output level in %, in a 0-20 mA or 4-20 mA scale (change scales with power-up option)

Lights when mA output (source or simulate) is active

Lights in diode test function

Lights in continuity function

Lights when relative reading is on

Lights when the battery is low

Show the input or output value

Lights when TouchHold is on

MIN MAX recording status indicators:

MIN means the display is showing the minimum recorded value.

MAX means the display is showing the maximum recorded value.

AVG means the display is showing the average value since starting recording (up to about 35 hours continuous recording time).

Rmeans MIN MAX recording is on.

15

Image 19
Contents 787 Limited Warranty & Limitation of Liability Table of Contents Index 787Introduction Read Safety Information before you use the meterContacting Fluke 787 Safety InformationProcessMeter Symbol Meaning International Symbols MeaningFluke 787 ProcessMeter How to Get StartedInput/Output Jacks Getting Acquainted with the MeterSource Current Function Input/Output Jacks Measurement FunctionsSimulate Transmitter Function Rotary Switch Positions for Measurements Pushbutton Actions FunctionsRotary Switch Positions for mA Output Default Function Pushbuttons Functions PushbuttonsCoarse PushbuttonElements of the Display Display Meaning ElementDisplay Element MA, DC, mV, AC Or kΩ, kHz Auto 400100030 Ranges Measuring a Composite SignalMeasuring Electrical Parameters Input ImpedanceDisplaying Minimum, Maximum, and Average Testing DiodesCompensating for Test Lead Resistance Using TouchHoldSource Mode Using the Current Output FunctionsSourcing Current Changing the Current Span Simulate ModeSimulating a Transmitter Adjustment MA Output Adjust PushbuttonsProducing a Steady mA Output MA Stepping Pushbuttons Manually Stepping the mA OutputAuto Ramping the mA Output MA Step Values Value for each span setting To 20 mAAction Taken Power-Up OptionsPower-Up Options Pushbutton DefaultGeneral Maintenance Battery LifeUsing the Holster and Flex-Stand MaintenanceUsing the Holster and Flex-Stand Replacing the Battery Replacing the BatteryReplacing a Fuse Replacing a Fuse If the Meter does not WorkReplacement Parts and Accessories Quantity Replacement PartsDescription Fluke PN or Model noMP8 Range V dc SpecificationsResolution DC Volts MeasurementDC Millivolts Measurement Range mV dc Resolution 400.0 Accuracy % of Reading + CountsAC Volts Measurement DC Current Measurement AC Current MeasurementOhms Measurement Range ResolutionMeasurement Current Frequency Counter Sensitivity Frequency Counter AccuracyInput Range Minimum Sensitivity rms Sinewave 5 Hz to 5 kHz Diode Test and Continuity Test General SpecificationsSource mode Simulate ModeCertifications CSA, UL, TÜV Index Knob positions, 9 Pushbuttons Loop supply, external Index 787