Graco 332574D Replace Chopper Chute Liner, Replace Muffler Filters Kit 24H280

Page 13

Replace Chopper Chute Liner

1.Follow Pressure Relief Procedure found within the RS Gun and Cutter, Operation-Repair manual.

2.Engage trigger lock.

3.Remove the cover.

4.Remove the cutter cover plate.

5.Replace the chute liner.

6.Installation is the reverse of removal.

Maintenance

Replace Muffler Filters (Kit 24H280)

1.Follow Pressure Relief Procedure found within the RS Gun and Cutter, Operation-Repair manual.

2.Engage trigger lock.

3.Remove the four screws holding the muffler cap on to the air motor.

4.Discard the old mufflers and replace.

5.Install the muffler cap and replace the four screws.

ti21013a

FIG. 9

FIG. 8

332574D

13

Image 13
Contents RS Gun Cutter Assemblies Important Safety InstructionsContents Related Manuals Key Component IdentificationAnvil to Blade Tension Lockdown Setup Anvil and Blade Replacement Cutter AssemblySee Replace Anvil and Replace Blades procedures on pages 11 OperationAdjust Anvil to Cutter Head Tension Adjust Cutter SpeedAdjust Blower Air Adjust Anvil to Idler Tension Adjust Cutter Air PressureNumber Strands Metric Air Motor Oiling MaintenanceTask Schedule Replace Anvil Adjust Anvil to Cutter Head Tension,Replace Blades Replace Muffler Filters Kit 24H280 Replace Chopper Chute LinerTroubleshooting Air Motor Component Removal RepairAir Motor Component Installation Air Motor Replacement Parts Qty Ref Part DescriptionPart Description Qty Ti21021a Ring Air Motor, 24E511 Part Description Qty Accessories Blade Cartridges Cover and ChutesCutter Chute Liner, 16P833 ToolsCutter Head Kits RS Cutter Assemblies Metric Technical DataGraco Information Graco Standard Warranty